• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
SensorsONE

SensorsONE

  • Products
  • Contact

0-10V to SqRt 0-10V Square Root Extraction Signal Conversion

Convert a 0 to 10 volts range measurement input signal into a square root extraction 0 to 10 volts output signal.

0-10V to SqRt 0-10V Square Root Extraction Signal Conversion

Contents

Toggle
  • Products
    • ISOCON 0-10V to SqRt 0-10V Signal Converter
      • ISOCON-6 24V ac/dc Powered 0-10V to SqRt 0-10V Signal Converter
      • ISOCON-3 Mains Powered 0-10V to SqRt 0-10V Signal Converter
  • Conversion Tool and Table

Products

ISOCON 0-10V to SqRt 0-10V Signal Converter

ISOCON 0-10V to SqRt 0-10V Signal ConverterThe ISOCON isolating signal converter is used to convert a 0-10V input measurement signal to a SqRt extraction 0-10V output signal.  The ISOCON can be easily mounted to a wall using a TS35 DIN rail.

ISOCON-6 24V ac/dc Powered 0-10V to SqRt 0-10V Signal Converter

  • SKU ID: s1-isocon-0155
  • Part No: II-ISOCON-6-G000-G-001
  • Input Type: 0-10V
  • Output Type: SqRt 0-10V
  • Supply: 12-36 Vdc or 12-32Vac
  • Isolation: Full 3-Port
  • Installation: DIN Rail TS35
  • Electrical Connections: Screw clamp with pressure plate

ISOCON-3 Mains Powered 0-10V to SqRt 0-10V Signal Converter

  • SKU ID: s1-isocon-0156
  • Part No: II-ISOCON-3-G000-G-001
  • Input Type: 0-10V
  • Output Type: SqRt 0-10V
  • Supply: 85-260Vac
  • Isolation: Full 3-Port
  • Installation: DIN Rail TS35
  • Electrical Connections: Screw clamp with pressure plate

Conversion Tool and Table

Calculate or look up a 0 to 10 V input scale value, to find the equivalent value over the sqrt extraction 0 to 10 V output scale.

Enter input value in V for a linear range from 0 to 10 V to calculate output value in V for a square root range from 0 to 10 V.

Input V
Output V
Sorry, a graphic could not be displayed here, because your browser does not support HTML5 Canvas.

Request product info for a 0...10 V linear input range to 0...10 V square root output scale measurement device.

Pick a value from the 0 to 10 V linear input range column of the conversion table below, and find the corresponding value in the 0 to 10 V square root output range column.

0...10 V 0...10 V 🔗

Primary Sidebar

Measurement Instrument Specifier

Specify a measurement instrument

Select your measurement instrument requirements

Universal Signal Converter

ISOCON universal signal converter

Convert any analogue measurement signal type with this Universal Signal Converter

Convert 0-10V signal to…

  • 4-20mA
  • 0-20mA
  • 0-5V
  • 1-5V
  • 10-0V
  • 0-10V sqrt

Wirelessly Measure & Log 0-10Vdc

Use this battery powered 0-10Vdc wireless transmitter to transmit readings to a receiver connected to USB, RS485, RS232, cellular network or analog output

Use this battery powered 0-10Vdc wireless transmitter to transmit readings to a receiver connected to USB, RS485, RS232, cellular network or analog output

Products

  • Pressure
  • Level
  • Temperature
  • Interfacing
  • Datalogging
  • Calibration
  • Wireless

Application Selection Guides

  • Absolute Pressure
  • Air Pressure
  • Barometric Pressure
  • Compound Pressure Ranges
  • Dual Temperature and Pressure
  • Hydrostatic Pressure
  • Low Pressure Range
  • Marine Approval
  • Overpressure Protection
  • Pressure Calibration
  • Submersible
  • Suction Pressure

Product Selection Guides

  • Data Loggers
  • Differential Pressure Sensors
  • Digital Pressure Gauges
  • Digital Pressure Sensors
  • Hydrostatic Liquid Level Sensors
  • Millivolt Output Pressure Transducers
  • Pressure Transducers
  • Pressure Transmitters
  • Voltage Output Pressure Transducers

Help Guides

  • Determining the hydrostatic pressure range for a tank level sensor
  • How to get a 10 volt signal from a 4-20mA output pressure sensor
  • Measuring vacuum with negative gauge or absolute ranges
  • Pressure Sensor Accuracy Specifications
  • Measuring liquid level in a sealed tank with a hydrostatic pressure sensor
  • What is the difference between gauge and absolute pressure measurement
  • Measuring the difference in air pressure between rooms
  • Measurement Accuracy
  • Symptons and Causes of Damage to Pressure Transducer Diaphragms
  • How to Connect a 4-20mA Current Loop Pressure Transmitter
  • Difference between vented and non-vented water level measurement
  • Determining water tank volume using hydrostatic pressure
  • What is difference between working, burst and over pressure
  • Process Connections
  • Advantages and Disadvantages of using a 4 to 20 mA Signal
  • Not reading zero when pressure is vented to atmosphere
  • Measuring the volume of liquid in a horizontal cylinder tank
  • Determining calibration error of Bourdon tube pressure gauge
  • What is the difference between zero offset and zero drift?
  • Why use 4-20mA and 3-15 psi rather than 0-20mA & 0-15psi
  • How do you measure the volume of a liquid using pressure
  • What is the difference between vacuum and absolute pressure
  • What does negative and positive gauge pressure mean
  • Measuring negative pressure using a positive differential pressure range
  • Measuring vacuum as a negative gauge pressure using a dp sensor
  • Measuring liquid level in a tank using a dp sensor
  • Measuring density of a liquid using a dp sensor
  • Pressure Sensor Technology Comparative Guide

Email Your Enquiry

enquiries@sensorsone.com
By clicking "OK" or continuing to use this website you are providing your consent to use cookies as described in our Privacy Policy

© 2026 SensorsONE Ltd, all rights reserved

  • Home
  • Products
  • Tools
  • Legal
  • Contact