• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
SensorsONE

SensorsONE

Measurement Instrumentation Products

  • Products
  • Tools
  • Contact

Input to Output Measurement Reading Converter

Linear Input Parameters
Input Unit [?]
Input Reading [?]
Low Input Limit [?]
High Input Limit [?]
Linear Output Parameters
Output Unit [?]
Low Output Limit [?]
High Output Limit [?]
Output Reading [?]

Click save settings to reload page with unique web page address for bookmarking and sharing the current tool settings

✕ clear settings

Invert the low & high range limit settings for the input or output side



Flip tool with current settings to swap I/O parameters and/or apply a square root extraction if required


Sorry, a graphic could not be displayed here, because your browser does not support HTML5 Canvas.

Contents

  • Related Tools
  • Universal Measurement to Fixed Range Output Signal Converters
  • Signal Input / Output Conversion Tables
    • 4 to 20 milliamps signal conversion
    • 0 to 20 milliamps signal conversion
    • 0 to 5 volts signal conversion
    • 1 to 5 volts signal conversion
    • 0 to 10 volts signal conversion
    • 0 to 50 volts signal conversion
    • 0.5 to 4.5 volts signal conversion
    • 0 to 1 volt signal conversion
    • 0 to 100 millivolts signal conversion
    • 0 to 50 millivolts signal conversion
    • 0 to 30 millivolts signal conversion
    • 0 to 20 millivolts signal conversion
  • User Guide
    • Input
      • Input Unit
      • Input Reading
      • Lowest Input
      • Highest Input
    • Output
      • Output Unit
      • Lowest Output
      • Highest Output
      • Output Reading – Answer
  • Help
    • Output to Input
    • Calibrating a measurement device
    • -50 to +150C in 4-20mA out
    • 4-20mA to 10-100C

Related Tools

  • Linear input to square root extraction output converter
  • Square root extraction input to linear output converter

Universal Measurement to Fixed Range Output Signal Converters

Select a universal measurement to signal converter to specify any measurement range and convert it to a fixed range analogue output signal:

  • 0-5V Output Signal Converter
  • 1-5V Output Signal Converter
  • 0-10V Output Signal Converter
  • 0.5-4.5V Output Signal Converter
  • 4-20mA Output Signal Converter
  • 0-20mA Output Signal Converter

Signal Input / Output Conversion Tables

Choose the required input to output signal conversion to view table.

4-20mA ↓ 0-20mA ↓ 0-5V ↓ 0-10V ↓ 1-5V ↓
20-4mA 4-20mA 4-20mA 4-20mA 4-20mA
0-20mA 20-0mA 0-20mA 0-20mA 0-20mA
0-5V 0-5V 5-0V 0-5V 0-5V
0-10V 0-10V 0-10V 10-0V 0-10V
1-5V 1-5V 1-5V 1-5V 5-1V

4 to 20 milliamps signal conversion

Conversion tables for 4 to 20 mA scale readings.

  • -10…+10V to 4…20mA Signal Conversion
  • -5…+5V to 4…20mA Signal Conversion
  • 0-100mV to 4-20mA Signal Conversion
  • 0-10V to 4-20mA Signal Conversion
  • 0-1V to 4-20mA Signal Conversion
  • 0-20mA to 4-20mA Signal Conversion
  • 0-20mV to 4-20mA Signal Conversion
  • 0-30mV to 4-20mA Signal Conversion
  • 0-50mV to 4-20mA Signal Conversion
  • 0-50V to 4-20mA Signal Conversion
  • 0-5V to 4-20mA Signal Conversion
  • 0.5-4.5V to 4-20mA Signal Conversion
  • 1-5V to 4-20mA Signal Conversion
  • 4-20mA square root extraction conversion to linear % full scale
  • 4-20mA to 0-10V Signal Conversion
  • 4-20mA to 0-20mA Signal Conversion
  • 4-20mA to 0-5V Signal Conversion
  • 4-20mA to 0.5-4.5V Signal Conversion
  • 4-20mA to 1-5V Signal Conversion
  • 4-20mA to 20-4mA Signal Inversion
  • 4…20mA to -10…+10V Bidirectional Signal Conversion
  • 4…20mA to -5…+5V Bidirectional Signal Conversion
  • Convert I to P (I/P) Control Signals & P to I (P/I) Monitoring Signals
  • Converting 4 to 20mA Linear Signal to and from Square Root Extraction Signal

0 to 20 milliamps signal conversion

Conversion tables for 0 to 20 mA scale readings.

  • 0-100mV to 0-20mA Signal Conversion
  • 0-10V to 0-20mA Signal Conversion
  • 0-1V to 0-20mA Signal Conversion
  • 0-20mA to 0-10V Signal Conversion
  • 0-20mA to 0-5V Signal Conversion
  • 0-20mA to 0.5-4.5V Signal Conversion
  • 0-20mA to 1-5V Signal Conversion
  • 0-20mA to 20-0mA Signal Inversion
  • 0-20mA to 4-20mA Signal Conversion
  • 0-50V to 0-20mA Signal Conversion
  • 0-5V to 0-20mA Signal Conversion
  • 0.5-4.5V to 0-20mA Signal Conversion
  • 1-5V to 0-20mA Signal Conversion
  • 4-20mA to 0-20mA Signal Conversion

0 to 5 volts signal conversion

Conversion tables for 0 to 5 V scale readings.

  • -10…+10V to -5…+5V Bidirectional Signal Conversion
  • -5…+5V to -10…+10V Bidirectional Signal Conversion
  • -5…+5V to 4…20mA Signal Conversion
  • 0-100mV to 0-5V Signal Conversion
  • 0-10V to 0-5V Signal Conversion
  • 0-1V to 0-5V Signal Conversion
  • 0-20mA to 0-5V Signal Conversion
  • 0-50V to 0-5V Signal Conversion
  • 0-5V to 0-10V Signal Conversion
  • 0-5V to 0-20mA Signal Conversion
  • 0-5V to 0.5-4.5V Signal Conversion
  • 0-5V to 1-5V Signal Conversion
  • 0-5V to 4-20mA Signal Conversion
  • 0-5V to 5-0V Signal Inversion
  • 0.5-4.5V to 0-5V Signal Conversion
  • 1-5V to 0-5V Signal Conversion
  • 4-20mA to 0-5V Signal Conversion
  • 4…20mA to -5…+5V Bidirectional Signal Conversion

1 to 5 volts signal conversion

Conversion tables for 1 to 5 V scale readings.

  • 0-100mV to 1-5V Signal Conversion
  • 0-10V to 1-5V Signal Conversion
  • 0-1V to 1-5V Signal Conversion
  • 0-20mA to 1-5V Signal Conversion
  • 0-50V to 1-5V Signal Conversion
  • 0-5V to 1-5V Signal Conversion
  • 0.5-4.5V to 1-5V Signal Conversion
  • 1-5V to 0-10V Signal Conversion
  • 1-5V to 0-20mA Signal Conversion
  • 1-5V to 0-5V Signal Conversion
  • 1-5V to 0.5-4.5V Signal Conversion
  • 1-5V to 4-20mA Signal Conversion
  • 1-5V to 5-1V Signal Inversion
  • 4-20mA to 1-5V Signal Conversion

0 to 10 volts signal conversion

Conversion tables for 0 to 10 V scale readings.

  • -10…+10V to -5…+5V Bidirectional Signal Conversion
  • -10…+10V to 4…20mA Signal Conversion
  • -5…+5V to -10…+10V Bidirectional Signal Conversion
  • 0-100mV to 0-10V Signal Conversion
  • 0-10V to 0-20mA Signal Conversion
  • 0-10V to 0-5V Signal Conversion
  • 0-10V to 0.5-4.5V Signal Conversion
  • 0-10V to 1-5V Signal Conversion
  • 0-10V to 10-0V Signal Inversion
  • 0-10V to 4-20mA Signal Conversion
  • 0-1V to 0-10V Signal Conversion
  • 0-20mA to 0-10V Signal Conversion
  • 0-20mV to 0-10V Signal Conversion
  • 0-30mV to 0-10V Signal Conversion
  • 0-50mV to 0-10V Signal Conversion
  • 0-50V to 0-10V Signal Conversion
  • 0-5V to 0-10V Signal Conversion
  • 0.5-4.5V to 0-10V Signal Conversion
  • 1-5V to 0-10V Signal Conversion
  • 4-20mA to 0-10V Signal Conversion
  • 4…20mA to -10…+10V Bidirectional Signal Conversion
  • Convert E to P (E/P) Control Signals & P to E (P/E) Monitoring Signals

0 to 50 volts signal conversion

Conversion tables for 0 to 50 V scale readings.

  • 0-50V to 0-10V Signal Conversion
  • 0-50V to 0-20mA Signal Conversion
  • 0-50V to 0-5V Signal Conversion
  • 0-50V to 1-5V Signal Conversion
  • 0-50V to 4-20mA Signal Conversion

0.5 to 4.5 volts signal conversion

Conversion tables for 0.5 to 4.5 V scale readings.

  • 0-10V to 0.5-4.5V Signal Conversion
  • 0-20mA to 0.5-4.5V Signal Conversion
  • 0-5V to 0.5-4.5V Signal Conversion
  • 0.5-4.5V to 0-10V Signal Conversion
  • 0.5-4.5V to 0-20mA Signal Conversion
  • 0.5-4.5V to 0-5V Signal Conversion
  • 0.5-4.5V to 1-5V Signal Conversion
  • 0.5-4.5V to 4-20mA Signal Conversion
  • 0.5-4.5V to 4.5-0.5V Signal Inversion
  • 1-5V to 0.5-4.5V Signal Conversion
  • 4-20mA to 0.5-4.5V Signal Conversion

0 to 1 volt signal conversion

Conversion tables for 0 to 1 V scale readings.

  • 0-1V to 0-10V Signal Conversion
  • 0-1V to 0-20mA Signal Conversion
  • 0-1V to 0-5V Signal Conversion
  • 0-1V to 1-5V Signal Conversion
  • 0-1V to 4-20mA Signal Conversion

0 to 100 millivolts signal conversion

Conversion tables for 0 to 100 mV scale readings.

  • 0-100mV to 0-10V Signal Conversion
  • 0-100mV to 0-20mA Signal Conversion
  • 0-100mV to 0-5V Signal Conversion
  • 0-100mV to 1-5V Signal Conversion
  • 0-100mV to 4-20mA Signal Conversion

0 to 50 millivolts signal conversion

Conversion tables for 0 to 50 mV scale readings.

  • 0-50mV to 0-10V Signal Conversion
  • 0-50mV to 4-20mA Signal Conversion

0 to 30 millivolts signal conversion

Conversion tables for 0 to 30 mV scale readings.

  • 0-30mV to 0-10V Signal Conversion
  • 0-30mV to 4-20mA Signal Conversion

0 to 20 millivolts signal conversion

Conversion tables for 0 to 20 mV scale readings.

  • 0-20mV to 0-10V Signal Conversion
  • 0-20mV to 4-20mA Signal Conversion

User Guide

This input to output conversion tool provides an easy way to determine the ideal linear output produced by a measurement instrument for any given input value. A conversion scale for each input and output range combination entered is also displayed below the calculated answer.

Input

Input Unit

Enter the measurement unit associated with the input values.

Input Reading

This is the input measurement reading you would like to convert.

Lowest Input

Enter the minimum possible value of the measurement device input range.  The value can be a negative or positive value and should be in the same engineering units as all the other Input values.

Highest Input

Enter the maximum possible value of the measurement device input range.  The value can be a negative or positive value and should be in the same engineering units as all the other Input values.

Output

Output Unit

Enter the measurement unit associated with the output values.

Lowest Output

Enter the minimum possible value of the measurement device output range.  The value can be a negative or positive value and should be in the same engineering units as all the other Output values.

Highest Output

Enter the maximum possible value of the measurement device output range.  The value can be a negative or positive value and should be in the same engineering units as all the other Output values.

Output Reading – Answer

This is the ideal Output from the measurement device for the Reading specified for the Input and excludes all measurement device errors and uncertainties.

Help

Output to Input

Can this calculator be used to convert an output to an input?

Yes, just switch them around and enter the output values to the input section and the input values to the output section to determine the ideal input value.

Calibrating a measurement device

Can I use this input/output calculator to calibrate a measurement device?

Yes, but bear in mind that the conversion does not include any errors related to the measurement device or the calibration reference standard, so it can be used to compare the actual measured output readings with the calculated ideal output readings.

-50 to +150C in 4-20mA out

What are the 4-20mA values for a -50 to +150C temperature tx?

Use this graphic to check what milliamp current is produced from a temperature transmitter with a range of -50 to +150 degC, or for more precise conversion values use this calculator to convert any value from -50…+150degC to 4-20mA.

minus 50 - 150degC to 4-20mA conversion scale

4-20mA to 10-100C

What 4-20mA values from a -10…+100C temperature transmitter?

Use this graphic to check what milliamp current is produced from a temperature transmitter with a range of -10 to +100 degC, or for more precise values use this calculator to convert any value from -10…+100degC to 4-20mA

minus 10-100degC to 4-20mA conversion scale

Primary Sidebar

Tool Sections

  • Density
  • Flow
  • Energy & Power
  • Electrical & Electromagnetic
  • Force, Load & Torque
  • Input & Output Signals
  • Length, Area & Volume
  • Liquid Depth & Level
  • Mass & Weight
  • Pressure
  • Speed & Acceleration
  • Temperature
  • Time & Frequency

Universal Signal Converter

ISOCON universal signal converter
Convert any analogue measurement signal type with this Universal Signal Converter

Product Selection Guides

  • Voltage Output Pressure Transducers
  • Pressure Transmitters
  • Pressure Transducers
  • Millivolt Output Pressure Transducers
  • Hydrostatic Liquid Level Sensors
  • Digital Pressure Sensors
  • Digital Pressure Gauges
  • Differential Pressure Sensors
  • Data Loggers

Application Selection Guides

  • Vacuum
  • Submersible
  • Oxygen Service
  • Low Pressure Range
  • Leak Testing
  • High Frequency Response
  • High Accuracy
  • Dual Temperature and Pressure
  • Barometric Pressure

Help Guides

  • What is the difference between sealed gauge and vented gauge reference?
  • Reduce calibration costs of analogue pressure gauges
  • Measuring vacuum with negative gauge or absolute ranges
  • Measuring the difference in air pressure between rooms
  • How to get a 10 volt signal from a 4-20mA output pressure sensor
  • How to Connect a 4-20mA Current Loop Pressure Transmitter
  • Determining the hydrostatic pressure range for a tank level sensor
  • Determine range of pressure gauge needed to measure force generated by hydraulic press
  • Converting non-vented depth readings & barometric pressure to true depth
  • Choosing PVC, PUR, FEP and TPE cable types

Online Measurement Tools

  • Temperature Transmitter 4-20mA Current Output Calculator
  • Pressure Transmitter 4-20mA Current Output Calculator
  • Pressure Transducer 1-5V Voltage Output Calculator
  • Pressure Converter
  • Measurement Reading to 4-20mA Signal Converter
  • Liquid Depth/Level to Hydrostatic Pressure Calculator
  • Input to Output Measurement Reading Converter
  • Force & Area to Pressure Calculator
  • Density to Specific Gravity Calculator

Email Your Enquiry

enquiries@sensorsone.com

© 2021 SensorsONE Ltd, all rights reserved

  • Home
  • Legal
  • Contact