Input to Output Measurement Reading Converter

Linear Input Parameters
Input Unit [?]
Input Reading [?]
Low Input Limit [?]
High Input Limit [?]
Linear Output Parameters
Output Unit [?]
Low Output Limit [?]
High Output Limit [?]
Output Reading [?]

Click save settings to reload page with unique web page address for bookmarking and sharing the current tool settings

✕ clear settings

Invert the low & high range limit settings for the input or output side



Flip tool with current settings to swap I/O parameters and/or apply a square root extraction if required


Sorry, a graphic could not be displayed here, because your browser does not support HTML5 Canvas.

Related Tools

  • Linear input to square root extraction output converter
  • Square root extraction input to linear output converter

Contents

Toggle
  • Universal Measurement to Fixed Range Output Signal Converters
  • User Guide
    • Input
      • Input Unit
      • Input Reading
      • Lowest Input
      • Highest Input
    • Output
      • Output Unit
      • Lowest Output
      • Highest Output
      • Output Reading – Answer
  • Help
    • Output to Input
    • Calibrating a measurement device
    • -50 to +150C in 4-20mA out
    • 4-20mA to 10-100C

Universal Measurement to Fixed Range Output Signal Converters

Select a universal measurement to signal converter to specify any measurement range and convert it to a fixed range analogue output signal:

  • 0-5V Output Signal Converter
  • 1-5V Output Signal Converter
  • 0-10V Output Signal Converter
  • 0.5-4.5V Output Signal Converter
  • 4-20mA Output Signal Converter
  • 0-20mA Output Signal Converter

User Guide

This input to output conversion tool provides an easy way to determine the ideal linear output produced by a measurement instrument for any given input value. A conversion scale for each input and output range combination entered is also displayed below the calculated answer.

Input

Input Unit

Enter the measurement unit associated with the input values.

Input Reading

This is the input measurement reading you would like to convert.

Lowest Input

Enter the minimum possible value of the measurement device input range. The value can be a negative or positive value and should be in the same engineering units as all the other Input values.

Highest Input

Enter the maximum possible value of the measurement device input range. The value can be a negative or positive value and should be in the same engineering units as all the other Input values.

Output

Output Unit

Enter the measurement unit associated with the output values.

Lowest Output

Enter the minimum possible value of the measurement device output range. The value can be a negative or positive value and should be in the same engineering units as all the other Output values.

Highest Output

Enter the maximum possible value of the measurement device output range. The value can be a negative or positive value and should be in the same engineering units as all the other Output values.

Output Reading – Answer

This is the ideal Output from the measurement device for the Reading specified for the Input and excludes all measurement device errors and uncertainties.

Help

Output to Input

Can this calculator be used to convert an output to an input?

Yes, just switch them around and enter the output values to the input section and the input values to the output section to determine the ideal input value.

Calibrating a measurement device

Can I use this input/output calculator to calibrate a measurement device?

Yes, but bear in mind that the conversion does not include any errors related to the measurement device or the calibration reference standard, so it can be used to compare the actual measured output readings with the calculated ideal output readings.

-50 to +150C in 4-20mA out

What are the 4-20mA values for a -50 to +150C temperature tx?

Use this graphic to check what milliamp current is produced from a temperature transmitter with a range of -50 to +150 degC, or for more precise conversion values use this calculator to convert any value from -50…+150degC to 4-20mA.

minus 50 - 150degC to 4-20mA conversion scale

4-20mA to 10-100C

What 4-20mA values from a -10…+100C temperature transmitter?

Use this graphic to check what milliamp current is produced from a temperature transmitter with a range of -10 to +100 degC, or for more precise values use this calculator to convert any value from -10…+100degC to 4-20mA

minus 10-100degC to 4-20mA conversion scale

Primary Sidebar

Tools

  • Unit Converters
  • Pressure
  • Liquid Level
  • Temperature & Heat
  • Electrical & Electromagnetic
  • Flow
  • Force, Load & Torque
  • Mass & Weight
  • Dimensions
  • Density
  • Time & Frequency
  • Speed & Acceleration
  • Energy & Power
  • Sensors & Instrumentation
  • Shapes
  • Movement & Motion
  • Travel & Transportation
  • Pricing & Quantities
  • Chemical Quantities
  • Health & Fitness

Tool Feedback

Please provide feedback on using this Input to Output Measurement Reading Converter.

Measurement Instrument Specifier

Specify a measurement instrument

Select your measurement instrument requirements

Universal Signal Converter

ISOCON universal signal converter

Convert any analogue measurement signal type with this Universal Signal Converter