This voltage signal to measurement conversion tool will convert an electrical signal within the range of 0 to 10 volts to the ideal reading of any linear measurement type and create an incremental volts conversion scale for each measurement range entered.
Formula
This tool uses the following formula to calculate the measurement reading from a voltage signal input over a 0-10V range:
Measurement Rdg = (High Limit – Low Limit) x V out / 10 + Low Limit
Parameters
Voltage Input Signal (0-10V) Reading
Add the analogue input signal reading in volts (V) that you want to convert between 0 and 10 V.
Measurement Unit
Enter the measurement unit associated with the output values.
Lowest Measurement
Add the minimum possible value for the measurement range of your instrument. For example zero would be a typical value for most instrumentation but you can also add negative (-) or positive (+) values as well. A value in any engineering units can be used as long as it relates to a linear measurement, and the same unit is used for the Highest value.
Highest Measurement
Add the maximum possible value for the measurement range of your instrument, e.g. full scale or full range. This value can be negative (-) or positive (+). Any engineering units can be used as long as it relates to a linear measurement, but the same unit must be used for the Lowest value.
Measurement Reading – Answer
This is the ideal converted measurement for your instrument and therefore represents a perfect reading excluding the measurement uncertainty error of your instrument. The answer value is displayed in the same engineering unit that you entered for the Lowest and Highest range points.
Featured 0 to 10 volts dc signal products
SSPT Subsea Wet-Mateable Electrical Connector Pressure Sensor - This stainless steel ceramic sensing diaphragm based subsea connector pressure sensor provides a unamplified ratiometric millivolt output or an amplified analogue output signal corresponding to ranges from 0…1 bar (14.50 psi) up to 400 bar ( 5800 psi).