This pressure transmitter 0 to 20 milliamp current output calculator provides a way to determine the output reading from the applied pressure and pressure transmitter range.
Sensors & Instrumentation Input/Output Calculators
Online web tools for converting and calculating the input and output parameters of measurement instrumentation.
Pressure Sensing Errors Calculator
This tool will calculate the total worst case & root sum squared pressure tolerance, long term stability, thermal effects error, room temperature accuracy or pressure value for a pressure sensing device.
Pressure Measurement Accuracy and Tolerance Calculator
This tool will calculate the tolerance value, accuracy factor or pressure value for a pressure measurement device.
Pressure Transducer 0.5-4.5V Voltage Output Calculator
This pressure transducer 0.5 to 4.5 volts amplified output calculator provides a way to determine the output reading from the applied pressure and pressure transducer range.
Pressure Transducer 1-5V Voltage Output Calculator
This pressure transducer 1 to 5 volts amplified output calculator provides a way to determine the output reading from the applied pressure and pressure transducer range.
Pressure Transducer 0-5V Voltage Output Calculator
This pressure transducer 0 to 5 volts amplified output calculator provides a way to determine the output reading from the applied pressure and pressure transducer range.
Pressure Transducer 0-10V Voltage Output Calculator
This pressure transducer 0 to 10 volts amplified output calculator provides a way to determine the output reading from the applied pressure and pressure transducer range.
Ratiometric V/V Signal to Measurement Converter
This ratiometric voltage input to measurement output converter provides a way to determine the measurement output reading and voltage input range from a ratiometric voltage input signal with a specified volts per volt span sensitivity, zero offset and supply voltage.
Measurement to Ratiometric V/V Signal Converter
This measurement to ratiometric voltage output calculator provides a way to determine the output reading and range of a ratiometric voltage signal sensing device from any measurement input, volts per volt span sensitivity, zero offset and supply voltage.
Ratiometric mV/V Signal to Measurement Converter
This ratiometric millivolt input to measurement output converter provides a way to determine the measurement output reading and millivolt input range from a ratiometric millivolt input signal with a specified millivolts per volt span sensitivity, zero offset and supply voltage.
Measurement to Ratiometric mV/V Signal Converter
This measurement to ratiometric millivolt output calculator provides a way to determine the output reading and range of a ratiometric millivolt signal sensing device from any measurement input, millivolts per volt span sensitivity, zero offset and supply voltage.
0-20mA Signal to Measurement Reading Converter
This current to measurement conversion tool will convert an electrical signal within the range of 0 to 20 milliamps to the ideal reading of any linear measurement type and create an incremental milliamp conversion scale for each measurement range entered.
0-10V Signal to Measurement Reading Converter
This voltage signal to measurement conversion tool will convert an electrical signal within the range of 0 to 10 volts to the ideal reading of any linear measurement type and create an incremental volts conversion scale for each measurement range entered.
0-5V Signal to Measurement Reading Converter
This voltage signal to measurement conversion tool will convert an electrical signal within the range of 0 to 5 volts to the ideal reading of any linear measurement type and create an incremental volts conversion scale for each measurement range entered.
1-5V Signal to Measurement Reading Converter
This voltage signal to measurement conversion tool will convert an electrical signal within the range of 1 to 5 volts to the ideal reading of any linear measurement type and create an incremental volts conversion scale for each measurement range entered.
0.5-4.5V Signal to Measurement Reading Converter
This voltage signal to measurement conversion tool will convert an electrical signal within the range of 0.5 to 4.5 volts to the ideal reading of any linear measurement type and create an incremental volts conversion scale for each measurement range entered.
DP Flow Transmitter Output Calculator
This differential pressure flow transmitter square root extraction 4 to 20 milliamp current output calculator provides a way to determine the flow output reading from the pressure drop measured across an orifice plate and the differential pressure transmitter range.
Liquid Level Transmitter 4-20mA Current Output Calculator
This liquid level transmitter 4 to 20 milliamp current output calculator provides a way to determine the output reading from the liquid level measurement and liquid level transmitter range
Flow Transmitter 4-20mA Current Output Calculator
This flow transmitter 4 to 20 milliamp current output calculator provides a way to determine the output reading from the measured flow and flow transmitter range.
Temperature Transmitter 4-20mA Current Output Calculator
This temperature transmitter 4 to 20 milliamp current output calculator provides a way to determine the output reading from the applied temperature and temperature transmitter range.
Pressure Transmitter 4-20mA Current Output Calculator
This pressure transmitter 4 to 20 milliamp current output calculator provides a way to determine the output reading from the applied pressure and pressure transmitter range.
Measurement Reading to 1-5V Signal Converter
This measurement to current converter tool will convert any linear input measurement reading into the ideal voltage output signal over a linear range of 1 to 5 volts, and display a 1-5V conversion scale for the chosen measurement range.
Measurement Reading to 0-5V Signal Converter
This measurement to voltage converter tool will convert any linear input measurement reading into the ideal voltage output signal over a linear range of 0 to 5 volts, and display a 0-5V conversion scale for the chosen measurement range.
Measurement Reading to 0-10V Signal Converter
This measurement to voltage converter tool will convert any linear input measurement reading into the ideal voltage output signal over a linear range of 0 to 10 volts, and display a 0-10V conversion scale for the chosen measurement range.
Strain Gauge Transducer Millivolt (mV) Output Calculator
This strain gauge transducer millivolt output calculator provides a way to determine the output reading and range from the applied stress, strain gauge transducer range and strain gauge output characteristics.
Measurement Reading to 0.5-4.5V Signal Converter
This measurement to voltage converter tool will convert any linear input measurement reading into the ideal voltage output signal over a linear range of 0.5 to 4.5 volts, and display a 0.5-4.5V conversion scale for the chosen measurement range.
Measurement Reading to 0-20mA Signal Converter
This measurement to current converter tool will convert any linear input measurement reading into the ideal current output signal over a linear range of 0 to 20 milliamps, and display a 0-20mA conversion scale for the chosen measurement range.
Torque Transducer Millivolt (mV) Output Calculator
This torque transducer millivolt output calculator provides a way to determine the output reading and range from the applied torque, torque transducer range and strain gauge output characteristics.
Pressure Transducer Millivolt (mV) Output Calculator
This pressure transducer millivolt output calculator provides a way to determine the output reading and range from the applied pressure, pressure transducer range and strain gauge output characteristics.
Load Cell Millivolt (mV) Output Calculator
This load cell millivolt output calculator provides a way to determine the output reading and range from the applied load, load cell range and strain gauge output characteristics.
Dead Weight Tester Pressure & Area to Mass Calculator
This online tool will calculate the required mass to be added to a dead weight tester pressure calibrator by entering the target pressure, the effective area of the piston-cylinder and the local gravity, m = P·A/g
Dead Weight Tester Mass & Area to Pressure Calculator
This online tool will calculate the pressure generated by a dead weight tester pressure calibrator by entering the total mass of added weights, the effective area of the piston-cylinder and the local gravity, P = m·g/A
Input to Output Measurement Reading Converter
This input to output converter will determine the linear output produced by any given linear input value and display a related conversion scale.
Convert Square Root Extraction Input to Linear Output
This sqrt extraction input to linear output converter provides an easy way to determine the ideal linear output for any given sqrt input value.
Convert Linear Input to Square Root Extraction Output
This linear input to sqrt extraction output converter provides an easy way to determine the ideal sqrt output produced for any given linear input value.
Calibration Error Calculator
Use this calibration error calculator to determine the accuracy of a measurement device which has a linear input and output characteristic.
Measurement to Digital Reading Converter
This measurement to digital converter will convert any linear measurement over a specified range to the equivalent digital decimal and binary number.
Bit to Measurement Resolution Converter
This bit to resolution converter will calculate the reading resolution of a DAC or ADC and answer in steps, %FS, ppm and decimal ratio.
SqRt Extraction 4-20mA Signal to Measurement Reading Converter
This tool will convert a sqrt 4-20 milliamp signal to a linear measurement over a specified measurement range and show a related conversion scale.
Measurement Reading to SqRt Extraction 4-20mA Signal Converter
This converter will convert any reading to a sq rt extraction 4-20mA signal. A sqrt 4-20mA conversion scale is also displayed for each measurement range.
Measurement Reading to 4-20mA Signal Converter
This tool converts linear measurement readings into a 4-20mA signal and displays a 4-20mA conversion scale for the corresponding measurement range.
4-20mA Signal to Measurement Reading Converter
This conversion tool will convert a 4-20mA electrical signal to the ideal reading for any linear measurement and display a conversion scale for each range.