• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to footer
SensorsONE

SensorsONE

Measurement Instrumentation Products

  • Products
  • Tools
  • Contact

Measurement to Ratiometric mV/V Signal Converter

Measurement Input Parameters
Unit [?]
Reading [?]
Full Range [?]
Millivolt Output Parameters
Supply Voltage (V) [?]
Span Sensitivity (mV/V) [?]
Zero Offset (mV) [?]
Full Range Output (mV) [?]
Output Reading (mV) [?]

Click to reload page with unique web address for bookmarking or sharing current settings

✕ clear settings

Sorry, a graphic could not be displayed here, because your browser does not support HTML5 Canvas.

Contents

  • Related Tools
  • User Guide
    • Measurement Input Parameters
      • Unit
      • Reading
      • Full Range
    • Millivolt Output Parameters
      • Supply Voltage (V)
      • Span Sensitivity (mV/V)
      • Zero Offset (mV)
      • Full Range Output (mV)
      • Output Reading (mV)

Related Tools

  • Measurement input to V/V output converter
  • V/V input to measurement output converter
  • mV/V input to measurement output converter

User Guide

This measurement to ratiometric millivolt output converter provides a way to determine the output reading and range of a ratiometric millivolt signal sensing device from any measurement input, millivolts per volt span sensitivity, zero offset and supply voltage. A conversion scale graphic for each measurement input range and ratiometric millivolt output range combination entered is also displayed underneath the calculated values.

Measurement Input Parameters

Unit

Enter the measurement unit for the quantity which is being measured , e.g. newtons, tonnes, micrometres, psi, degrees Celsius, etc…

Reading

This is the quantity measured that you wish to convert to a millivolt output reading.

Full Range

Enter the maximum quantity that the ratiometric mV/V signal sensing device will measure.

Millivolt Output Parameters

Supply Voltage (V)

This is the excitation voltage used to power the ratiometric mV/V signal sensing device. The millivolt output of a ratiometric mV/V signal sensing device is linearly proportional to the excitation voltage.

Span Sensitivity (mV/V)

This is the full span output per supply volt characteristic for the ratiometric mV/V signal sensing device.

Zero Offset (mV)

This is the measured output of the ratiometric mV/V signal sensing device, powered by the specified supply voltage, without any measurement input applied.

Full Range Output (mV)

This is the full range output of the ratiometric mV/V signal sensing device in millivolts, powered by the specified supply voltage, with the maximum measurable quantity applied.

Output Reading (mV)

This is the expected ideal ratiometric mV/V signal sensing device output in millivolts for the measured quantity specified.

Primary Sidebar

Tool Sections

  • Density
  • Flow
  • Energy & Power
  • Force, Load & Torque
  • Input & Output Signals
  • Length, Area & Volume
  • Liquid Depth & Level
  • Mass & Weight
  • Pressure
  • Speed & Acceleration
  • Temperature
  • Time & Frequency

Universal Signal Converter

ISOCON universal signal converter
Convert any analogue measurement signal type with this Universal Signal Converter

Product Selection Guides

  • Pressure Transmitters
  • Pressure Transducers
  • Liquid Level Sensors
  • Digital Pressure Gauges
  • Data Loggers

Application Selection Guides

  • Vacuum
  • Submersible
  • Low Pressure Range
  • Leak Testing
  • High Frequency Response
  • Dual Temperature and Pressure
  • Barometric Pressure

Help Guides

  • Reduce calibration costs of analogue pressure gauges
  • Measuring the difference in air pressure between rooms
  • How to get a 10 volt signal from a 4-20mA output pressure sensor
  • How to Connect a 4-20mA Current Loop Pressure Transmitter
  • Determining the hydrostatic pressure range for a tank level sensor
  • Choosing PVC, PUR, FEP and TPE cable types

Online Measurement Tools

  • Temperature Transmitter 4-20mA Current Output Calculator
  • Pressure Transmitter 4-20mA Current Output Calculator
  • Pressure Transducer 1-5V Voltage Output Calculator
  • Pressure Converter
  • Measurement Reading to 4-20mA Signal Converter
  • Liquid Depth/Level to Hydrostatic Pressure Calculator
  • Input to Output Measurement Reading Converter
  • Force & Area to Pressure Calculator
  • Density to Specific Gravity Calculator

Product Enquiry

Send us your enquiry for a product associated with this Measurement to Ratiometric mV/V Signal Converter page, and get assistance with selecting a product for your application.

Email Your Enquiry

enquiries@sensorsone.com

Footer

By clicking "OK" or continuing to use this website you are providing your consent to use cookies as described in our Privacy Policy

© 2021 SensorsONE Ltd, all rights reserved

  • Home
  • Legal
  • Contact