Click save settings to reload page with unique web page address for bookmarking and sharing the current tool settings
Invert the low & high range limits for the measurement input settings
Flip tool with current settings to swap measurement input (I) with 0-5V output parameters
- 20 kg/cm² range 5Vdc output pressure transducer for potable water
- Irrigation water pressure transducer for pressures up to 60 bar
- 5 psig range 0-5V output pressure sensor for air blowing use
- 3 MPa absolute range 0-5Vdc output nitrogen gas pressure sensor for aerospace testing use
Related Tools
- Pressure sensor calculator
- Pressure units converter
- Universal measurement to 0-5V output converter
- Input to output converter
- 4-20mA pressure transmitter output calculator
- 0-20mA pressure transmitter output calculator
- 0-10V pressure transducer output calculator
- 1-5V pressure transducer output calculator
- 0.5-4.5V pressure transducer output calculator
- mV/V pressure transducer output calculator
User Guide
This pressure transmitter 0 to 5 volts voltage output calculator provides a way to determine the output reading from the applied pressure and pressure transducer range. A conversion scale graphic for each pressure and 0-5 volts output range combination entered is also displayed below the calculated values.
Formula
This pressure transducer output calculator uses the following formula to calculate the output over a 0-5V range:
Linear V out = 5 x ((Rdg – Low Limit) / (High Limit – Low Limit))
Parameters
Unit
Enter the unit used for measuring pressure, e.g. bar, psi, kPa, inH2O etc…
Reading
This is the applied pressure measured by the pressure transducer that you wish to convert to a 0 to 5 V voltage output reading.
Low Limit
Enter the lowest pressure that the pressure transducer will measure. For example zero would be a typical value for most voltage output pressure transducers, but you can also add negative (-) or positive (+) values as well. Please enter the value in the same pressure units as specified for all other input values.
High Limit
Enter the maximum pressure that the amplified pressure transducer will measure.
Output Reading (V)
This is the expected ideal pressure transducer voltage output signal in volts for the applied pressure specified.
- 30 psi g air pressure transducer with 0 to 5 volts output
- -5 to +5 psig bidirectional low range 0-5 volts output pressure sensor
- 100 mbar gauge range 0-5 volts output stainless steel pressure sensor
- -0.5 to +0.5 bar gauge 0-5 volts output compound range pressure sensor