A bidirectional low range pressure transmitter for venturi tube use to measure pressure of air in a venturi tube over a range of -200 to 200 Pa from the 6.6mm dia x 11mm barbed connections process connection, and sending the corresponding 4-20mA signal through the M12 x 1.5 cable glands with 5 internal screw terminals electrical connection.
FSM
-0.1 to +0.1 inH2O g range 4-20mA signal air pressure sensor and display for pharmaceutical manufacturing use
A positive/negative gauge low range pressure sensor and digital display for pharmaceutical manufacturing use to measure pressure of air over a range of -0.1 to 0.1 inH2O g from the 6mm flexible tubing connection, and sending the corresponding 4-20mA signal through the M12 x 1.5 cable gland and internal screw terminal electrical connection.
PrimAtü 10 Low Cost Low Range Differential Air Pressure Transducer
The PrimAtü 10 low cost low range differential air pressure transducer can detect and display both positive and negative differential pressure variations of very low low pressure ranges from 0.5 up to 1000 mbar/hPa, and output the pressure as a 4-20mA, 0-20mA or a 0-10Vdc analog output.
DPC Low Range Pressure Controller and Calibrator
The DPC low range pressure controller calibrator measures and generates low range pressures over 1, 10, 100 or 1000 mbar, and can be used as a pressure measurement device or as a test and calibration device for pressure sensors and pressure switches.
0.1 inH2O differential range 0-10Vdc output between rooms air pressure sensor
A pressure sensor for between rooms use to measure pressure difference of air over a range of 0 to 0.1 inH2O differential from two flexible tube connections process connections, and sending the corresponding 0-10Vdc signal through the pcb screw terminals electrical connection.
10Pa diff range 0-20mA output air pressure sensor for automotive component testing
A very low range pressure sensor for automotive component testing use to measure pressure of air over a range of 0 to 10 Pa diff from two barbed tube hose connections, and sending the corresponding 0-20mA signal through the DIN plug electrical connection.
1 hPa Positive Room Pressure Sensor, Switch & Display
A 100 Pascal range positive room pressure sensor with a 0-10 volt analogue output signal relating to the inside/outside room pressure difference.
Using 25 mbar DP sensor on vacuum below 0.2 bar absolute
I would like to measure a differential pressure of 0 to 25 mbar in a vacuum of < 0.2 bar absolute pressure.
+/- 1 inH2O compound range pressure sensor
Low compound range pressure sensor with a -1 to +1 inH2O measurement range and corresponding 4-20mA current output for use on air systems.
Clean room temp, RH and pressure monitoring
Clean room monitor for temperature, relative humidity 0 to 99% RH and pressure from minus 100 to +100 Pa
Bi-directional -20 to +100 Pa clean room air diff pressure transmitter
Air diff pressure transmitter for HVAC application to measure in the range of -20 to +100 Pa with an active analog output of 4 – 20 mA
100 pascals range brick kiln and dryer air pressure logger and sensor
Logger with low bidirectional range differential sensor for recording brick kiln and dryer air pressures over the compound range of -100 to +100 Pa.
DPS Low Differential Pressure Transmitter
Ultra low differential pressure transmitter for HVAC applications with 4-20mA current loop or amplified voltage output signal in pressure ranges from 0.1 mb up to 1 bar differential.
Clean Room Monitor for Air Differential Pressure, Temperature and Humidity – PMDS4
The PMDS4 clean room monitor is designed for positive and negative monitoring of differential air pressure between the inside and outside of a clean room.
Negative room pressure monitor and logger for multiple zones
Monitoring system to measure negative room pressure inside each of five interior zones to eliminate the spread of dust.
Minus 0.25 inWG differential pressure transmitter for negative air pressure difference
Pressure transmitter which will measure o to -0.25 inches of water differential air pressure and output a linear signal over a current scale of 4 to 20 milliamps.
100 Pa bi-directional range differential air pressure transmitter
Bi-directional low range 4 to 20 milliamp differential pressure transmitter covering an air pressure range from -100 to +100 pascals.
Compound +/-2.5 mbar DP transmitter, indicator & alarm switch
Differential pressure transmitter with a signal & alarm warning output for measuring a compound scale from a vacuum of -2.5mbar to a pressure of 2.5mbar.
0-100Pa air pressure transducer with a 0-10V analog output
Air pressure transducer for measuring 0 to 100 pascals with an analog output signal of 0 to 10 volts.
10 mmWC draft fan differential pressure transmitter
Low range dp transmitter for measuring 0… -10mmWC to maintain constant negative pressure across an induced draft fan fitted with a variable frequency drive.
20 pascal differential pressure transducer for clean rooms
Voltage output transducer for cleanroom differential pressure measurement. This transducer has 0 to 20 pascals range for measuring very small positive pressure.
Minus 100 pascal suction pressure transmitter
Very low range suction pressure transmitter for monitoring negative pressures up to 100 pascals.
0.06 inWG positive air pressure transmitter for HVAC blower fan control
Air pressure differential transmitter with 4-20 mA output used in a blower speed control loop for building positive pressure up to 0.06″WG draft pressure in an HVAC system.
Minus 10 pascal vacuum pressure transmitter
Vacuum pressure transmitter for measuring a very low suction pressure from 0 to minus 10 pascals, with an electrical signal output of 4 to 20 milliamps.
10 mbar range differential pressure calibrator
We need a differential pressure calibrator for checking a 2 mbar differential pressure transmitter?
1.5 inWG differential pressure transducer to control positive pressure inside a building
Low range differential pressure transducer to monitor difference of up to 1.5 inches of water gauge between outside pressure and inside pressure.
150 Pa low range differential pressure switch and indicator
Combined low range digital pressure indicator and voltage free contact relay pressure switch for monitoring and control over the differential range 0 to 150 pascals.
1kPa diff pressure transducer for building air ventilation monitoring
Differential pressure transducer capable of measuring over 0 to 1 kilopascal for building ventilation applications.
Bidirectional -50 to +50 Pa diff pressure transmitter with user calibration adjustment
Bi-directional 4 to 20 milliamp output pressure transmitter for measuring a diff pressure from -50 to +50 pascals.
0 to 9 pascals range pressure gauge
Low Pascal range pressure gauge for measuring from 0 to 9 pascals and provide a digital readout of the pressure readings?