0…100 mbar, 0…1.5 psi, 0…40 inH2O, or 0…10 kPa pressure range, 4…20 mA output signal pressure sensors.
These pressure sensors will measure from 0 to 100 millibars, 0 to 1.5 pounds per square inch, 0 to 40 inches of water column, or 0 to 10 kilopascals pressure ranges, and convert the measured pressure to a corresponding output signal from 4 to 20 milliamps.
- 1.5 psig range 4-20mA output freshwater tank fluid level pressure sensor for farming use
- -10…30 kPa g compound range inert gas pressure transmitter for ship IG system
- High reading rate for measuring dynamic pressures to -200psf
- Stainless steel 316L wetted parts 100 mbar ATEX pressure transmitter
- Gas supply 100 mbar static pressure transmitter for boiler room
- 100 mbar wet/wet 4 to 20mA differential pressure sensor and display
- Fresh water compatible submersible 1mH2O range 4-20mA output pressure sensor
- Hygienic atex approved 100mbar pressure transmitter for pharmaceutical application
- 1000 mbar vacuum transmitter for use with waste toner dust
- Flood proof, vacuum pressure transmitter for use on fuel tank system
- Landfill biogas extraction well depressure pressure transmitter
- Powder filter blockage monitoring pressure transmitter
- 3 wire 4 to 20mA pressure transmitter to measure 100 mbar
- 100 mbar abs vacuum transmitter with a 5 bar overpressure
- 1.5 psi wet/wet DP transmitter for line pressures up to 1,885 psi
- Argon gas compatible pressure sensor for measuring up to 100 mbar
- Trichloroethylene compatible 100 mbar Ex pressure transmitter
- 100mb leak testing dp transmitter with 1mb accuracy & 10bar overpressure rating
- 10 kPa orifice plate differential pressure transmitter for water flow measurement
- 40 inH2O g OEM pressure transmitter with 4-20mA current output
- G1/4 internal thread pressure transmitter for measuring 0-100mb
- Natural gas booster pump inlet/outlet pressure transmitters for backup power generators
Calibration Tables
0…100 mbar to 4…20 mA
Use this table to determine the exact calibration points for a 0…100 millibars range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…100 mbar to 4…20 mA converter and enter any value.
% Scale | 0…100mbar | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 10.00 | 5.60 |
20 | 20.00 | 7.20 |
30 | 30.00 | 8.80 |
40 | 40.00 | 10.40 |
50 | 50.00 | 12.00 |
60 | 60.00 | 13.60 |
70 | 70.00 | 15.20 |
80 | 80.00 | 16.80 |
90 | 90.00 | 18.40 |
100 | 100.00 | 20.00 |
Request product information for a 0...100 mbar to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.
0…1.5 psi to 4…20 mA
Use this table to determine the exact calibration points for a 0…1.5 pounds per square inch range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…1.5 psi to 4…20 mA converter and enter any value.
% Scale | 0…1.5psi | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 0.15 | 5.60 |
20 | 0.30 | 7.20 |
30 | 0.45 | 8.80 |
40 | 0.60 | 10.40 |
50 | 0.75 | 12.00 |
60 | 0.90 | 13.60 |
70 | 1.05 | 15.20 |
80 | 1.20 | 16.80 |
90 | 1.35 | 18.40 |
100 | 1.50 | 20.00 |
Request product information for a 0...1.5 psi to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.
0…40 inH2O to 4…20 mA
Use this table to determine the exact calibration points for a 0…40 inches of water column range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…40 inH2O to 4…20 mA converter and enter any value.
% Scale | 0…40inH2O | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 4.00 | 5.60 |
20 | 8.00 | 7.20 |
30 | 12.00 | 8.80 |
40 | 16.00 | 10.40 |
50 | 20.00 | 12.00 |
60 | 24.00 | 13.60 |
70 | 28.00 | 15.20 |
80 | 32.00 | 16.80 |
90 | 36.00 | 18.40 |
100 | 40.00 | 20.00 |
Request product information for a 0...40 inH2O to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.
0…10 kPa to 4…20 mA
Use this table to determine the exact calibration points for a 0…10 kilopascals range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…10 kPa to 4…20 mA converter and enter any value.
% Scale | 0…10kPa | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 1.00 | 5.60 |
20 | 2.00 | 7.20 |
30 | 3.00 | 8.80 |
40 | 4.00 | 10.40 |
50 | 5.00 | 12.00 |
60 | 6.00 | 13.60 |
70 | 7.00 | 15.20 |
80 | 8.00 | 16.80 |
90 | 9.00 | 18.40 |
100 | 10.00 | 20.00 |
Request product information for a 0...10 kPa to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.