DP transmitter for measuring pressure difference between two pressure points which can tolerate up a very high overload pressure independently on either the positive or negative side port or both together at the same time.
DPT200
-3 to 4 mbar dp range 4-20mA ATEX approved biogas pressure sensor for process control use on a 1bar line
A low range differential pressure sensor for process control use to measure pressure of biogas over a range of -3 to 4 mbar diff on a 1 bar biogas line from two 1/4 NPT female process connections, and sending the corresponding 4-20mA signal through the weatherproof cable electrical connection.
-3 to 3 psi dp range high accuracy 4-20mA air pressure transmitter for water treatment use
A high accuracy low bi-directional range differential pressure transmitter for water treatment use to measure pressure of air over a range of -3 to 3 psi differential from two 1/4”-18 NPT internal process connections, and sending the corresponding 4-20mA signal through the 1/2" NPT internal cable gland electrical connection.
1 mbar range 4-20mA output biogas pressure transmitter for controlling blower fan connected to a covered lagoon
An intrinsically safe very low range pressure transmitter to measure pressure of biogas under covered lagoon to control a blower fan, over a range of 0 to 1 mbar g from the 1/4 inch NPT female tapered thread process connection, and sending the corresponding 4-20mA signal through the terminal clamps and M20 x 1.5 cable gland electrical connection.
1 inH2O differential intrinsically safe 4-20mA out air pressure sensor for HVAC use
A low range intrinsically safe pressure sensor for HVAC use to measure pressure of air over a range of 0 to 1 inH2O differential from two G1/4 female process connections, and sending the corresponding 4-20mA signal through the M20 x 1.5 cable gland electrical connection.
10bar differential range 4-20mA output air pressure sensor for leak testing use on a 110bar line
A high accuracy pressure sensor for leak testing use to measure pressure of air over a range of 0 to 10 bar diff on a 110 bar air line from two 1/4 NPT female process connections, and sending the corresponding 4-20mA signal through the M12 connector electrical connection.
ATEX rated room ±100 Pa differential pressure transmitter
Differential pressure transmitter with a -100 to +100 Pascal range for measuring the difference in pressure between the inside and the outside of a room, in an ATEX zone.
1psi wet/wet differential pressure transmitter for 2000 psi line pressure
Differential pressure transmitter with an output scale to measure over 0 to 1 psi pressure drop on a 2000 psi system line pressure.
1 bar range pressure transmitter with 400 bar overpressure protection
Pressure transmitter with a 400 bar maximum overpressure capability for measuring over a 0 to 1 bar pressure range.
4 inch water column range 4-20mA differential pressure sensor for liquids
Low range wet/wet dp sensor for measuring differential pressure of a liquid from 0 to 4 inches of water column.
10 kPa orifice plate differential pressure transmitter for water flow measurement
Pressure sensor for measuring the differential pressure generated by water flowing through an orifice plate in a pipe, and converting the output to a water flow measurement.
Ethylene glycol antifreeze compatible 300 pascal dp sensor
300 pascal differential pressure sensor for measuring ethylene glycol 50/50 antifreeze coolant.
DPT200 Pressurised Tank Level Differential Pressure Transmitter
Pressurised tank liquid level differential pressure cell transmitter for process plant storage.
Low range ATEX approved 100 Pascal range DP transmitter
The DPT200 is a robust ATEX approved differential pressure transmitter which has a very low range of 100Pa.
Solvent compatible +/-100mWG dp transmitter with PTFE seals
Differential pressure transmitters to use on Nitrogen and/or air containing low levels of flammable solvents.