Pressure transmitter with a 400 bar maximum overpressure capability for measuring over a 0 to 1 bar pressure range.
This pressure transmitter has built-in overload protection to withstand an overpressure condition up to 400 bar without damaging or affecting operation of the transmitter over the 0 to 1 bar range, once the overpressure condition has passed.
This version of the DPT 200 has been setup to provide a 4…20 mA current output over the 0…1 bar range and can be used to measure differential pressure between to points or gauge pressure with the low pressure / negative side connection left open to atmosphere.
DPT200 High Overpressure Pressure Transmitter
- DPT200 data sheet
- Part No: 343-D-4-H-17-L-AL-AK0-N20-0-N20-0-02-11-1-000
- Pressure Datum: Differential Pressure
- Differential Pressure Range: 0 ‐ 25 mbar up to 0 ‐ 2.5 bar
- Factory Set Range: 0 ‐ 1 bar
- Maximum Static Pressure: 400 bar
- Display: With backlit display
- Output: 4-20mA/ 2-wire with HART
- Accuracy: <±0.075% / FSO IEC 60770
- Electrical Connection: Terminal clamp / M20x1.5 Cable Gland
- Housing Material: Stainless Steel 304
- Process Connection: Internal thread 1/4″ ‐ 18 NPT
- Process Connection Material: Stainless Steel 1.4301 (304)
- Diaphragm Material: Stainless Steel 1.4435 (316L)
- Seal Material: FKM
- Special Options: None
- Supply Voltage: 12 ‐ 42 V dc
- IP Rating: 67
- Media Temperature: -40 to +100°C
- Operating Temperature: -20 to +65°C
- Approvals: None