0…10 bar, 0…150 psi, 0…10 kg/cm2, or 0…1 MPa pressure range, 4…20 mA output signal pressure sensors.
These pressure sensors will measure from 0 to 10 bars, 0 to 150 pounds per square inch, 0 to 10 kilograms per square centimetre, or 0 to 1 megapascal pressure ranges, and convert the measured pressure to a corresponding output signal from 4 to 20 milliamps.
Sea-water corrosion resistant 10 bar pressure transmitter
3in1 ATEX 10bar pump pressure transducer, gauge & switch
Measuring steam pressure up to 10bar with analog/digital output
Autoclave pressure sensor and display with 10 bar range
150psi freshwater differential pressure sensor & panel indicator
Zero and span adjustable 10 bar ATEX pressure transmitter
10 barg range 4-20mA output saltwater pressure sensor for sea water heat exchanger use
Lube oil pressure sensor for use on ship engines to measure up to 10 bar
SIL2 approved 10 bar pressure transducer with 4 to 20 mA output
10 barg range 4-20mA output steam pressure sensor for food processing use
10 bar g range wireless pressure sensing kit for BMS monitoring use
-1 to 10 bar ATEX pressure sensor
150psig range 4-20mA high temperature pressure sensor for steam generator system use
Submersible sensor for measuring sludge pressure in pipe
10 bar absolute 4-20mA natural gas pressure sensor for high temperature research use
10 bar pressure transmitter with integral temperature probe for 0-100degC
10 kg/cm2 g range 4-20ma output ceramic diaphragm pressure sensor
SF6 gas leak testing, high resolution pressure transmitter
2barg, 10barg range wireless pressure sensing kit for production monitoring use
Intrinsically safe 10 barg range 4-20mA output natural gas pressure sensor
1000 kPa g range natural gas 4-20mA output pressure sensor and switch
320 degF steam temperature, 100 psi pressure transmitter
10 bar g steam pressure transmitter, indicator and PNP switch
10 bar g steam pressure transmitter
Seawater pressure transmitter with 10 bar range and marine certification
10bar differential range 4-20mA output air pressure sensor for leak testing use on a 110bar line
150psig range wireless pressure sensing kit for leak testing use
150 psi absolute IS 4-20mA oxygen clean pressure transducer for research use
Calibration Tables
0…10 bar to 4…20 mA
Use this table to determine the exact calibration points for a 0…10 bars range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…10 bar to 4…20 mA converter and enter any value.
% Scale | 0…10bar | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 1.00 | 5.60 |
20 | 2.00 | 7.20 |
30 | 3.00 | 8.80 |
40 | 4.00 | 10.40 |
50 | 5.00 | 12.00 |
60 | 6.00 | 13.60 |
70 | 7.00 | 15.20 |
80 | 8.00 | 16.80 |
90 | 9.00 | 18.40 |
100 | 10.00 | 20.00 |
Request product information for a 0...10 bar to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.
0…150 psi to 4…20 mA
Use this table to determine the exact calibration points for a 0…150 pounds per square inch range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…150 psi to 4…20 mA converter and enter any value.
% Scale | 0…150psi | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 15.00 | 5.60 |
20 | 30.00 | 7.20 |
30 | 45.00 | 8.80 |
40 | 60.00 | 10.40 |
50 | 75.00 | 12.00 |
60 | 90.00 | 13.60 |
70 | 105.00 | 15.20 |
80 | 120.00 | 16.80 |
90 | 135.00 | 18.40 |
100 | 150.00 | 20.00 |
Request product information for a 0...150 psi to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.
0…10 kg/cm2 to 4…20 mA
Use this table to determine the exact calibration points for a 0…10 kilograms per square centimetre range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…10 kg/cm2 to 4…20 mA converter and enter any value.
% Scale | 0…10kg/cm2 | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 1.00 | 5.60 |
20 | 2.00 | 7.20 |
30 | 3.00 | 8.80 |
40 | 4.00 | 10.40 |
50 | 5.00 | 12.00 |
60 | 6.00 | 13.60 |
70 | 7.00 | 15.20 |
80 | 8.00 | 16.80 |
90 | 9.00 | 18.40 |
100 | 10.00 | 20.00 |
Request product information for a 0...10 kg/cm2 to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.
0…1 MPa to 4…20 mA
Use this table to determine the exact calibration points for a 0…1 megapascal range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…1 MPa to 4…20 mA converter and enter any value.
% Scale | 0…1MPa | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 0.10 | 5.60 |
20 | 0.20 | 7.20 |
30 | 0.30 | 8.80 |
40 | 0.40 | 10.40 |
50 | 0.50 | 12.00 |
60 | 0.60 | 13.60 |
70 | 0.70 | 15.20 |
80 | 0.80 | 16.80 |
90 | 0.90 | 18.40 |
100 | 1.00 | 20.00 |
Request product information for a 0...1 MPa to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.