0…2 bar or 0…30 psi pressure range, 0…10 V, 0…5 V, or 1…5 V output signal pressure sensors.
These pressure sensors will measure from 0 to 2 bars or 0 to 30 pounds per square inch pressure ranges, and convert the measured pressure to a corresponding output signal from 0 to 10 volts, 0 to 5 volts, or 1 to 5 volts.
Water pump input/output testing pressure sensor with 30 psi absolute range
-1 to +2 bar g compound pressure transducer with 5Vdc output
30 psi g air pressure transducer with 0 to 5 volts output
30 psi barometric pressure transducer with 0-10Vdc out
Elevated freshwater tank level 30 psig range 0-5Vdc out pressure sensor
2 bar gauge range 0-5 volts output ceramic diaphragm air pressure sensor
5 to 30 psi abs range 0-10Vdc output air pressure sensor for air compression use
High temperature -1…2 barg range 0…10Vdc out heat pipe pressure sensor for research use
2barg, 10barg range wireless pressure sensing kit for production monitoring use
30psig range wireless pressure sensing kit for production monitoring use
Find out more about our 2 bar, 30 psi Range 0-10 V, 0-5 V, 1-5 V Output Pressure Sensors to determine which product options and capabilities will best meet your application requirements.
Calibration Tables
0…2 bar to 0…10 V
Use this table to determine the exact calibration points for a 0…2 bars range to 0…10 volts output pressure sensor. For additional calibration points use our 0…2 bar to 0…10 V converter and enter any value.
| % Scale | 0…2bar | 0…10V |
|---|---|---|
| 0 | 0.00 | 0.00 |
| 10 | 0.20 | 1.00 |
| 20 | 0.40 | 2.00 |
| 30 | 0.60 | 3.00 |
| 40 | 0.80 | 4.00 |
| 50 | 1.00 | 5.00 |
| 60 | 1.20 | 6.00 |
| 70 | 1.40 | 7.00 |
| 80 | 1.60 | 8.00 |
| 90 | 1.80 | 9.00 |
| 100 | 2.00 | 10.00 |
Request product information for a 0...2 bar to 0...10 V pressure sensor that matches the input and output measurement range from the calibration table above.
0…30 psi to 0…10 V
Use this table to determine the exact calibration points for a 0…30 pounds per square inch range to 0…10 volts output pressure sensor. For additional calibration points use our 0…30 psi to 0…10 V converter and enter any value.
| % Scale | 0…30psi | 0…10V |
|---|---|---|
| 0 | 0.00 | 0.00 |
| 10 | 3.00 | 1.00 |
| 20 | 6.00 | 2.00 |
| 30 | 9.00 | 3.00 |
| 40 | 12.00 | 4.00 |
| 50 | 15.00 | 5.00 |
| 60 | 18.00 | 6.00 |
| 70 | 21.00 | 7.00 |
| 80 | 24.00 | 8.00 |
| 90 | 27.00 | 9.00 |
| 100 | 30.00 | 10.00 |
Request product information for a 0...30 psi to 0...10 V pressure sensor that matches the input and output measurement range from the calibration table above.
0…2 bar to 0…5 V
Use this table to determine the exact calibration points for a 0…2 bars range to 0…5 volts output pressure sensor. For additional calibration points use our 0…2 bar to 0…5 V converter and enter any value.
| % Scale | 0…2bar | 0…5V |
|---|---|---|
| 0 | 0.00 | 0.00 |
| 10 | 0.20 | 0.50 |
| 20 | 0.40 | 1.00 |
| 30 | 0.60 | 1.50 |
| 40 | 0.80 | 2.00 |
| 50 | 1.00 | 2.50 |
| 60 | 1.20 | 3.00 |
| 70 | 1.40 | 3.50 |
| 80 | 1.60 | 4.00 |
| 90 | 1.80 | 4.50 |
| 100 | 2.00 | 5.00 |
Request product information for a 0...2 bar to 0...5 V pressure sensor that matches the input and output measurement range from the calibration table above.
0…30 psi to 0…5 V
Use this table to determine the exact calibration points for a 0…30 pounds per square inch range to 0…5 volts output pressure sensor. For additional calibration points use our 0…30 psi to 0…5 V converter and enter any value.
| % Scale | 0…30psi | 0…5V |
|---|---|---|
| 0 | 0.00 | 0.00 |
| 10 | 3.00 | 0.50 |
| 20 | 6.00 | 1.00 |
| 30 | 9.00 | 1.50 |
| 40 | 12.00 | 2.00 |
| 50 | 15.00 | 2.50 |
| 60 | 18.00 | 3.00 |
| 70 | 21.00 | 3.50 |
| 80 | 24.00 | 4.00 |
| 90 | 27.00 | 4.50 |
| 100 | 30.00 | 5.00 |
Request product information for a 0...30 psi to 0...5 V pressure sensor that matches the input and output measurement range from the calibration table above.
0…2 bar to 1…5 V
Use this table to determine the exact calibration points for a 0…2 bars range to 1…5 volts output pressure sensor. For additional calibration points use our 0…2 bar to 1…5 V converter and enter any value.
| % Scale | 0…2bar | 1…5V |
|---|---|---|
| 0 | 0.00 | 1.00 |
| 10 | 0.20 | 1.40 |
| 20 | 0.40 | 1.80 |
| 30 | 0.60 | 2.20 |
| 40 | 0.80 | 2.60 |
| 50 | 1.00 | 3.00 |
| 60 | 1.20 | 3.40 |
| 70 | 1.40 | 3.80 |
| 80 | 1.60 | 4.20 |
| 90 | 1.80 | 4.60 |
| 100 | 2.00 | 5.00 |
Request product information for a 0...2 bar to 1...5 V pressure sensor that matches the input and output measurement range from the calibration table above.
0…30 psi to 1…5 V
Use this table to determine the exact calibration points for a 0…30 pounds per square inch range to 1…5 volts output pressure sensor. For additional calibration points use our 0…30 psi to 1…5 V converter and enter any value.
| % Scale | 0…30psi | 1…5V |
|---|---|---|
| 0 | 0.00 | 1.00 |
| 10 | 3.00 | 1.40 |
| 20 | 6.00 | 1.80 |
| 30 | 9.00 | 2.20 |
| 40 | 12.00 | 2.60 |
| 50 | 15.00 | 3.00 |
| 60 | 18.00 | 3.40 |
| 70 | 21.00 | 3.80 |
| 80 | 24.00 | 4.20 |
| 90 | 27.00 | 4.60 |
| 100 | 30.00 | 5.00 |
Request product information for a 0...30 psi to 1...5 V pressure sensor that matches the input and output measurement range from the calibration table above.