0…3.5 mH2O or 0…11 ftH2O liquid level range, 4…20 mA, 0…10 V, or 0…5 V output signal hydrostatic liquid level sensors.
These hydrostatic liquid level sensors will measure from 0 to 3.5 metres of water column or 0 to 11 feet of water column liquid level ranges, and convert the measured level to a corresponding output signal from 4 to 20 milliamps, 0 to 10 volts, or 0 to 5 volts.
- Contaminated groundwater submersible plastic body 5 psi pressure transducer & display
- Sewage level transmitter for submerging in low depths to 5 psi
- 12ft high ink tank screw-in 4-20mA output level sensor
- Diesel exhaust fluid tank level sensor for fleet storage
- 140 inch range rangeable 4-20mA output wastewater level sensor and display for external fitting
- Submersible rainwater tank level sensor for measuring 3.5m depth
- Water temperature depth sensor for cooling tower sump
Calibration Tables
0…3.5 mH2O to 4…20 mA
Use this table to determine the exact calibration points for a 0…3.5 metres of water column range to 4…20 milliamps output hydrostatic liquid level sensor. For additional calibration points use our 0…3.5 mH2O to 4…20 mA converter and enter any value.
% Scale | 0…3.5mH2O | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 0.35 | 5.60 |
20 | 0.70 | 7.20 |
30 | 1.05 | 8.80 |
40 | 1.40 | 10.40 |
50 | 1.75 | 12.00 |
60 | 2.10 | 13.60 |
70 | 2.45 | 15.20 |
80 | 2.80 | 16.80 |
90 | 3.15 | 18.40 |
100 | 3.50 | 20.00 |
Request product information for a 0...3.5 mH2O to 4...20 mA hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…11 ftH2O to 4…20 mA
Use this table to determine the exact calibration points for a 0…11 feet of water column range to 4…20 milliamps output hydrostatic liquid level sensor. For additional calibration points use our 0…11 ftH2O to 4…20 mA converter and enter any value.
% Scale | 0…11ftH2O | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 1.10 | 5.60 |
20 | 2.20 | 7.20 |
30 | 3.30 | 8.80 |
40 | 4.40 | 10.40 |
50 | 5.50 | 12.00 |
60 | 6.60 | 13.60 |
70 | 7.70 | 15.20 |
80 | 8.80 | 16.80 |
90 | 9.90 | 18.40 |
100 | 11.00 | 20.00 |
Request product information for a 0...11 ftH2O to 4...20 mA hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…3.5 mH2O to 0…10 V
Use this table to determine the exact calibration points for a 0…3.5 metres of water column range to 0…10 volts output hydrostatic liquid level sensor. For additional calibration points use our 0…3.5 mH2O to 0…10 V converter and enter any value.
% Scale | 0…3.5mH2O | 0…10V |
---|---|---|
0 | 0.00 | 0.00 |
10 | 0.35 | 1.00 |
20 | 0.70 | 2.00 |
30 | 1.05 | 3.00 |
40 | 1.40 | 4.00 |
50 | 1.75 | 5.00 |
60 | 2.10 | 6.00 |
70 | 2.45 | 7.00 |
80 | 2.80 | 8.00 |
90 | 3.15 | 9.00 |
100 | 3.50 | 10.00 |
Request product information for a 0...3.5 mH2O to 0...10 V hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…11 ftH2O to 0…10 V
Use this table to determine the exact calibration points for a 0…11 feet of water column range to 0…10 volts output hydrostatic liquid level sensor. For additional calibration points use our 0…11 ftH2O to 0…10 V converter and enter any value.
% Scale | 0…11ftH2O | 0…10V |
---|---|---|
0 | 0.00 | 0.00 |
10 | 1.10 | 1.00 |
20 | 2.20 | 2.00 |
30 | 3.30 | 3.00 |
40 | 4.40 | 4.00 |
50 | 5.50 | 5.00 |
60 | 6.60 | 6.00 |
70 | 7.70 | 7.00 |
80 | 8.80 | 8.00 |
90 | 9.90 | 9.00 |
100 | 11.00 | 10.00 |
Request product information for a 0...11 ftH2O to 0...10 V hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…3.5 mH2O to 0…5 V
Use this table to determine the exact calibration points for a 0…3.5 metres of water column range to 0…5 volts output hydrostatic liquid level sensor. For additional calibration points use our 0…3.5 mH2O to 0…5 V converter and enter any value.
% Scale | 0…3.5mH2O | 0…5V |
---|---|---|
0 | 0.00 | 0.00 |
10 | 0.35 | 0.50 |
20 | 0.70 | 1.00 |
30 | 1.05 | 1.50 |
40 | 1.40 | 2.00 |
50 | 1.75 | 2.50 |
60 | 2.10 | 3.00 |
70 | 2.45 | 3.50 |
80 | 2.80 | 4.00 |
90 | 3.15 | 4.50 |
100 | 3.50 | 5.00 |
Request product information for a 0...3.5 mH2O to 0...5 V hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…11 ftH2O to 0…5 V
Use this table to determine the exact calibration points for a 0…11 feet of water column range to 0…5 volts output hydrostatic liquid level sensor. For additional calibration points use our 0…11 ftH2O to 0…5 V converter and enter any value.
% Scale | 0…11ftH2O | 0…5V |
---|---|---|
0 | 0.00 | 0.00 |
10 | 1.10 | 0.50 |
20 | 2.20 | 1.00 |
30 | 3.30 | 1.50 |
40 | 4.40 | 2.00 |
50 | 5.50 | 2.50 |
60 | 6.60 | 3.00 |
70 | 7.70 | 3.50 |
80 | 8.80 | 4.00 |
90 | 9.90 | 4.50 |
100 | 11.00 | 5.00 |
Request product information for a 0...11 ftH2O to 0...5 V hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.