0…5 mH2O or 0…16 ftH2O liquid level range, 4…20 mA, 0…10 V, or 0…5 V output signal hydrostatic liquid level sensors.
These hydrostatic liquid level sensors will measure from 0 to 5 metres of water column or 0 to 16 feet of water column liquid level ranges, and convert the measured level to a corresponding output signal from 4 to 20 milliamps, 0 to 10 volts, or 0 to 5 volts.
Dairy silo level sensor & display unit for reading content in litres
200 inch range 0-10Vdc output level sensor for soap water with up to 50% NaOH concentration
Abstraction pump protection using a screw-on hydrostatic level transmitter in a tidal river
Desalination plant feed tank submersible level sensor
Low cost, upstream/downstream, 5m range, fresh-water, weir level sensor
5m deep sewage wastewater submersible level sensor
Remote water tank level monitoring via GSM mobile network
7.5 psig range 0-5V output submersible silicon diaphragm liquid level sensor
5 metre range high accuracy 4-20mA output non-corrosive liquid level sensor with G1/4 male external fitting
Seawater intake channel submersible level sensor with 5m range and 4-20mA output
Leachate holding tank submersible level sensor for 5 metre depth
Calibration Tables
0…5 mH2O to 4…20 mA
Use this table to determine the exact calibration points for a 0…5 metres of water column range to 4…20 milliamps output hydrostatic liquid level sensor. For additional calibration points use our 0…5 mH2O to 4…20 mA converter and enter any value.
| % Scale | 0…5mH2O | 4…20mA |
|---|---|---|
| 0 | 0.00 | 4.00 |
| 10 | 0.50 | 5.60 |
| 20 | 1.00 | 7.20 |
| 30 | 1.50 | 8.80 |
| 40 | 2.00 | 10.40 |
| 50 | 2.50 | 12.00 |
| 60 | 3.00 | 13.60 |
| 70 | 3.50 | 15.20 |
| 80 | 4.00 | 16.80 |
| 90 | 4.50 | 18.40 |
| 100 | 5.00 | 20.00 |
Request product information for a 0...5 mH2O to 4...20 mA hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…16 ftH2O to 4…20 mA
Use this table to determine the exact calibration points for a 0…16 feet of water column range to 4…20 milliamps output hydrostatic liquid level sensor. For additional calibration points use our 0…16 ftH2O to 4…20 mA converter and enter any value.
| % Scale | 0…16ftH2O | 4…20mA |
|---|---|---|
| 0 | 0.00 | 4.00 |
| 10 | 1.60 | 5.60 |
| 20 | 3.20 | 7.20 |
| 30 | 4.80 | 8.80 |
| 40 | 6.40 | 10.40 |
| 50 | 8.00 | 12.00 |
| 60 | 9.60 | 13.60 |
| 70 | 11.20 | 15.20 |
| 80 | 12.80 | 16.80 |
| 90 | 14.40 | 18.40 |
| 100 | 16.00 | 20.00 |
Request product information for a 0...16 ftH2O to 4...20 mA hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…5 mH2O to 0…10 V
Use this table to determine the exact calibration points for a 0…5 metres of water column range to 0…10 volts output hydrostatic liquid level sensor. For additional calibration points use our 0…5 mH2O to 0…10 V converter and enter any value.
| % Scale | 0…5mH2O | 0…10V |
|---|---|---|
| 0 | 0.00 | 0.00 |
| 10 | 0.50 | 1.00 |
| 20 | 1.00 | 2.00 |
| 30 | 1.50 | 3.00 |
| 40 | 2.00 | 4.00 |
| 50 | 2.50 | 5.00 |
| 60 | 3.00 | 6.00 |
| 70 | 3.50 | 7.00 |
| 80 | 4.00 | 8.00 |
| 90 | 4.50 | 9.00 |
| 100 | 5.00 | 10.00 |
Request product information for a 0...5 mH2O to 0...10 V hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…16 ftH2O to 0…10 V
Use this table to determine the exact calibration points for a 0…16 feet of water column range to 0…10 volts output hydrostatic liquid level sensor. For additional calibration points use our 0…16 ftH2O to 0…10 V converter and enter any value.
| % Scale | 0…16ftH2O | 0…10V |
|---|---|---|
| 0 | 0.00 | 0.00 |
| 10 | 1.60 | 1.00 |
| 20 | 3.20 | 2.00 |
| 30 | 4.80 | 3.00 |
| 40 | 6.40 | 4.00 |
| 50 | 8.00 | 5.00 |
| 60 | 9.60 | 6.00 |
| 70 | 11.20 | 7.00 |
| 80 | 12.80 | 8.00 |
| 90 | 14.40 | 9.00 |
| 100 | 16.00 | 10.00 |
Request product information for a 0...16 ftH2O to 0...10 V hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…5 mH2O to 0…5 V
Use this table to determine the exact calibration points for a 0…5 metres of water column range to 0…5 volts output hydrostatic liquid level sensor. For additional calibration points use our 0…5 mH2O to 0…5 V converter and enter any value.
| % Scale | 0…5mH2O | 0…5V |
|---|---|---|
| 0 | 0.00 | 0.00 |
| 10 | 0.50 | 0.50 |
| 20 | 1.00 | 1.00 |
| 30 | 1.50 | 1.50 |
| 40 | 2.00 | 2.00 |
| 50 | 2.50 | 2.50 |
| 60 | 3.00 | 3.00 |
| 70 | 3.50 | 3.50 |
| 80 | 4.00 | 4.00 |
| 90 | 4.50 | 4.50 |
| 100 | 5.00 | 5.00 |
Request product information for a 0...5 mH2O to 0...5 V hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…16 ftH2O to 0…5 V
Use this table to determine the exact calibration points for a 0…16 feet of water column range to 0…5 volts output hydrostatic liquid level sensor. For additional calibration points use our 0…16 ftH2O to 0…5 V converter and enter any value.
| % Scale | 0…16ftH2O | 0…5V |
|---|---|---|
| 0 | 0.00 | 0.00 |
| 10 | 1.60 | 0.50 |
| 20 | 3.20 | 1.00 |
| 30 | 4.80 | 1.50 |
| 40 | 6.40 | 2.00 |
| 50 | 8.00 | 2.50 |
| 60 | 9.60 | 3.00 |
| 70 | 11.20 | 3.50 |
| 80 | 12.80 | 4.00 |
| 90 | 14.40 | 4.50 |
| 100 | 16.00 | 5.00 |
Request product information for a 0...16 ftH2O to 0...5 V hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.