0…1 mH2O or 0…3 ftH2O liquid level range, 4…20 mA, 0…10 V, or 0…5 V output signal hydrostatic liquid level sensors.
These hydrostatic liquid level sensors will measure from 0 to 1 metre of water column or 0 to 3 feet of water column liquid level ranges, and convert the measured level to a corresponding output signal from 4 to 20 milliamps, 0 to 10 volts, or 0 to 5 volts.
- 1 metre screw-in plastic level sensor for biodiesel/sulphuric acid mixture with 4 to 20 mA output
- Sea water tank level sensor for 30 cm depth variation on ship
- Industrial dishwasher 0-1m 0-10Vdc water level sensor
- Automatic fire pump engine 48 inch range 0-10Vdc output diesel tank level sensor
- 120cm range 4-20mA submersible chemical tank level sensor for farm water line mineral injection
- 100 mbarg range 0-5 volts output IP68 silicon diaphragm liquid level sensor
- Fresh water compatible submersible 1mH2O range 4-20mA output pressure sensor
- High temperature water level transmitter for measuring up to 1 mWG
- 0 to 5 volt output sensor for measuring low seawater level
- 1 metre depth range Titanium housing submersible transducer
- Protecting low range river level sensor from storm surges
- 1 metre deep raw sewage ATEX approved submersible level transmitter
- Raw leachate feed tank depth probe
Calibration Tables
0…1 mH2O to 4…20 mA
Use this table to determine the exact calibration points for a 0…1 metre of water column range to 4…20 milliamps output hydrostatic liquid level sensor. For additional calibration points use our 0…1 mH2O to 4…20 mA converter and enter any value.
% Scale | 0…1mH2O | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 0.10 | 5.60 |
20 | 0.20 | 7.20 |
30 | 0.30 | 8.80 |
40 | 0.40 | 10.40 |
50 | 0.50 | 12.00 |
60 | 0.60 | 13.60 |
70 | 0.70 | 15.20 |
80 | 0.80 | 16.80 |
90 | 0.90 | 18.40 |
100 | 1.00 | 20.00 |
Request product information for a 0...1 mH2O to 4...20 mA hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…3 ftH2O to 4…20 mA
Use this table to determine the exact calibration points for a 0…3 feet of water column range to 4…20 milliamps output hydrostatic liquid level sensor. For additional calibration points use our 0…3 ftH2O to 4…20 mA converter and enter any value.
% Scale | 0…3ftH2O | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 0.30 | 5.60 |
20 | 0.60 | 7.20 |
30 | 0.90 | 8.80 |
40 | 1.20 | 10.40 |
50 | 1.50 | 12.00 |
60 | 1.80 | 13.60 |
70 | 2.10 | 15.20 |
80 | 2.40 | 16.80 |
90 | 2.70 | 18.40 |
100 | 3.00 | 20.00 |
Request product information for a 0...3 ftH2O to 4...20 mA hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…1 mH2O to 0…10 V
Use this table to determine the exact calibration points for a 0…1 metre of water column range to 0…10 volts output hydrostatic liquid level sensor. For additional calibration points use our 0…1 mH2O to 0…10 V converter and enter any value.
% Scale | 0…1mH2O | 0…10V |
---|---|---|
0 | 0.00 | 0.00 |
10 | 0.10 | 1.00 |
20 | 0.20 | 2.00 |
30 | 0.30 | 3.00 |
40 | 0.40 | 4.00 |
50 | 0.50 | 5.00 |
60 | 0.60 | 6.00 |
70 | 0.70 | 7.00 |
80 | 0.80 | 8.00 |
90 | 0.90 | 9.00 |
100 | 1.00 | 10.00 |
Request product information for a 0...1 mH2O to 0...10 V hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…3 ftH2O to 0…10 V
Use this table to determine the exact calibration points for a 0…3 feet of water column range to 0…10 volts output hydrostatic liquid level sensor. For additional calibration points use our 0…3 ftH2O to 0…10 V converter and enter any value.
% Scale | 0…3ftH2O | 0…10V |
---|---|---|
0 | 0.00 | 0.00 |
10 | 0.30 | 1.00 |
20 | 0.60 | 2.00 |
30 | 0.90 | 3.00 |
40 | 1.20 | 4.00 |
50 | 1.50 | 5.00 |
60 | 1.80 | 6.00 |
70 | 2.10 | 7.00 |
80 | 2.40 | 8.00 |
90 | 2.70 | 9.00 |
100 | 3.00 | 10.00 |
Request product information for a 0...3 ftH2O to 0...10 V hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…1 mH2O to 0…5 V
Use this table to determine the exact calibration points for a 0…1 metre of water column range to 0…5 volts output hydrostatic liquid level sensor. For additional calibration points use our 0…1 mH2O to 0…5 V converter and enter any value.
% Scale | 0…1mH2O | 0…5V |
---|---|---|
0 | 0.00 | 0.00 |
10 | 0.10 | 0.50 |
20 | 0.20 | 1.00 |
30 | 0.30 | 1.50 |
40 | 0.40 | 2.00 |
50 | 0.50 | 2.50 |
60 | 0.60 | 3.00 |
70 | 0.70 | 3.50 |
80 | 0.80 | 4.00 |
90 | 0.90 | 4.50 |
100 | 1.00 | 5.00 |
Request product information for a 0...1 mH2O to 0...5 V hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…3 ftH2O to 0…5 V
Use this table to determine the exact calibration points for a 0…3 feet of water column range to 0…5 volts output hydrostatic liquid level sensor. For additional calibration points use our 0…3 ftH2O to 0…5 V converter and enter any value.
% Scale | 0…3ftH2O | 0…5V |
---|---|---|
0 | 0.00 | 0.00 |
10 | 0.30 | 0.50 |
20 | 0.60 | 1.00 |
30 | 0.90 | 1.50 |
40 | 1.20 | 2.00 |
50 | 1.50 | 2.50 |
60 | 1.80 | 3.00 |
70 | 2.10 | 3.50 |
80 | 2.40 | 4.00 |
90 | 2.70 | 4.50 |
100 | 3.00 | 5.00 |
Request product information for a 0...3 ftH2O to 0...5 V hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.