0…1 bar or 0…15 psi pressure range, 0…10 V, 0…5 V, or 1…5 V output signal pressure sensors.
These pressure sensors will measure from 0 to 1 bar or 0 to 15 pounds per square inch pressure ranges, and convert the measured pressure to a corresponding output signal from 0 to 10 volts, 0 to 5 volts, or 1 to 5 volts.
- 15 psig range 0-5V output stainless steel pressure sensor
- 1 bar absolute pressure transducer with 0-5Vdc for freshwater
- 15 psi g liquid pressure transducer with 0 to 10 Vdc output
- 15 psi absolute vacuum range 0-5 volts output pressure sensor
- Minus 14 psi gauge suction range 0 to 5 volts output pressure sensor
- Depression vacuum 1 bar absolute range 0-5V output automotive test pressure sensor
- 40 ftH2Og range 1-5Vdc output freshwater pressure sensor for environmental monitoring use
- 15psig 0-5Vdc out air gasoline mixture pressure sensor for automotive supercharger booster testing
- -15psig 0-10V out negative pressure transducer and display for air extraction use
- 1000 mbar absolute vacuum range 0-10Vdc output air pressure sensor for research use
- 15psig 0-10Vdc output pressure sensor for nitrogen filled antenna line leak testing use
- Leak testing at 0.5 bar to detect 200 Pascal pressure drop
- Adjustable range pressure sensor for scaling -1 to +1 bar g
- High resolution, 1 bar absolute, 0-10 Vdc out pressure sensor
Calibration Tables
0…1 bar to 0…10 V
Use this table to determine the exact calibration points for a 0…1 bar range to 0…10 volts output pressure sensor. For additional calibration points use our 0…1 bar to 0…10 V converter and enter any value.
% Scale | 0…1bar | 0…10V |
---|---|---|
0 | 0.00 | 0.00 |
10 | 0.10 | 1.00 |
20 | 0.20 | 2.00 |
30 | 0.30 | 3.00 |
40 | 0.40 | 4.00 |
50 | 0.50 | 5.00 |
60 | 0.60 | 6.00 |
70 | 0.70 | 7.00 |
80 | 0.80 | 8.00 |
90 | 0.90 | 9.00 |
100 | 1.00 | 10.00 |
Request product information for a 0...1 bar to 0...10 V pressure sensor that matches the input and output measurement range from the calibration table above.
0…15 psi to 0…10 V
Use this table to determine the exact calibration points for a 0…15 pounds per square inch range to 0…10 volts output pressure sensor. For additional calibration points use our 0…15 psi to 0…10 V converter and enter any value.
% Scale | 0…15psi | 0…10V |
---|---|---|
0 | 0.00 | 0.00 |
10 | 1.50 | 1.00 |
20 | 3.00 | 2.00 |
30 | 4.50 | 3.00 |
40 | 6.00 | 4.00 |
50 | 7.50 | 5.00 |
60 | 9.00 | 6.00 |
70 | 10.50 | 7.00 |
80 | 12.00 | 8.00 |
90 | 13.50 | 9.00 |
100 | 15.00 | 10.00 |
Request product information for a 0...15 psi to 0...10 V pressure sensor that matches the input and output measurement range from the calibration table above.
0…1 bar to 0…5 V
Use this table to determine the exact calibration points for a 0…1 bar range to 0…5 volts output pressure sensor. For additional calibration points use our 0…1 bar to 0…5 V converter and enter any value.
% Scale | 0…1bar | 0…5V |
---|---|---|
0 | 0.00 | 0.00 |
10 | 0.10 | 0.50 |
20 | 0.20 | 1.00 |
30 | 0.30 | 1.50 |
40 | 0.40 | 2.00 |
50 | 0.50 | 2.50 |
60 | 0.60 | 3.00 |
70 | 0.70 | 3.50 |
80 | 0.80 | 4.00 |
90 | 0.90 | 4.50 |
100 | 1.00 | 5.00 |
Request product information for a 0...1 bar to 0...5 V pressure sensor that matches the input and output measurement range from the calibration table above.
0…15 psi to 0…5 V
Use this table to determine the exact calibration points for a 0…15 pounds per square inch range to 0…5 volts output pressure sensor. For additional calibration points use our 0…15 psi to 0…5 V converter and enter any value.
% Scale | 0…15psi | 0…5V |
---|---|---|
0 | 0.00 | 0.00 |
10 | 1.50 | 0.50 |
20 | 3.00 | 1.00 |
30 | 4.50 | 1.50 |
40 | 6.00 | 2.00 |
50 | 7.50 | 2.50 |
60 | 9.00 | 3.00 |
70 | 10.50 | 3.50 |
80 | 12.00 | 4.00 |
90 | 13.50 | 4.50 |
100 | 15.00 | 5.00 |
Request product information for a 0...15 psi to 0...5 V pressure sensor that matches the input and output measurement range from the calibration table above.
0…1 bar to 1…5 V
Use this table to determine the exact calibration points for a 0…1 bar range to 1…5 volts output pressure sensor. For additional calibration points use our 0…1 bar to 1…5 V converter and enter any value.
% Scale | 0…1bar | 1…5V |
---|---|---|
0 | 0.00 | 1.00 |
10 | 0.10 | 1.40 |
20 | 0.20 | 1.80 |
30 | 0.30 | 2.20 |
40 | 0.40 | 2.60 |
50 | 0.50 | 3.00 |
60 | 0.60 | 3.40 |
70 | 0.70 | 3.80 |
80 | 0.80 | 4.20 |
90 | 0.90 | 4.60 |
100 | 1.00 | 5.00 |
Request product information for a 0...1 bar to 1...5 V pressure sensor that matches the input and output measurement range from the calibration table above.
0…15 psi to 1…5 V
Use this table to determine the exact calibration points for a 0…15 pounds per square inch range to 1…5 volts output pressure sensor. For additional calibration points use our 0…15 psi to 1…5 V converter and enter any value.
% Scale | 0…15psi | 1…5V |
---|---|---|
0 | 0.00 | 1.00 |
10 | 1.50 | 1.40 |
20 | 3.00 | 1.80 |
30 | 4.50 | 2.20 |
40 | 6.00 | 2.60 |
50 | 7.50 | 3.00 |
60 | 9.00 | 3.40 |
70 | 10.50 | 3.80 |
80 | 12.00 | 4.20 |
90 | 13.50 | 4.60 |
100 | 15.00 | 5.00 |
Request product information for a 0...15 psi to 1...5 V pressure sensor that matches the input and output measurement range from the calibration table above.