0…4 mH2O or 0…13 ftH2O liquid level range, 4…20 mA, 0…10 V, or 0…5 V output signal hydrostatic liquid level sensors.
These hydrostatic liquid level sensors will measure from 0 to 4 metres of water column or 0 to 13 feet of water column liquid level ranges, and convert the measured level to a corresponding output signal from 4 to 20 milliamps, 0 to 10 volts, or 0 to 5 volts.
Dirty water, sludge & sewerage tank level 400 mbar pressure sensor
Immersible water level sensor for 4 metre deep cold water storage tank
HART flameproof (Ex d) re-scalable level transmitter for hydrostatic head up to 2 metres
Canola oil tank hygienic level sensor & indicator with high temperature protection
4 metre range submersible freshwater level transmitter
Floating dry dock ballast tank 14ft range 4-20mA output submersible seawater level sensor
River level sensor for run-of-the-river hydropower monitoring up to 4m
Filtered rainwater cistern 13ft range 4-20mA submersible drinking and cooking water level sensor
4000mm range 0-5Vdc output diesel tank level sensor for external fitting
Calibration Tables
0…4 mH2O to 4…20 mA
Use this table to determine the exact calibration points for a 0…4 metres of water column range to 4…20 milliamps output hydrostatic liquid level sensor. For additional calibration points use our 0…4 mH2O to 4…20 mA converter and enter any value.
% Scale | 0…4mH2O | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 0.40 | 5.60 |
20 | 0.80 | 7.20 |
30 | 1.20 | 8.80 |
40 | 1.60 | 10.40 |
50 | 2.00 | 12.00 |
60 | 2.40 | 13.60 |
70 | 2.80 | 15.20 |
80 | 3.20 | 16.80 |
90 | 3.60 | 18.40 |
100 | 4.00 | 20.00 |
Request product information for a 0...4 mH2O to 4...20 mA hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…13 ftH2O to 4…20 mA
Use this table to determine the exact calibration points for a 0…13 feet of water column range to 4…20 milliamps output hydrostatic liquid level sensor. For additional calibration points use our 0…13 ftH2O to 4…20 mA converter and enter any value.
% Scale | 0…13ftH2O | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 1.30 | 5.60 |
20 | 2.60 | 7.20 |
30 | 3.90 | 8.80 |
40 | 5.20 | 10.40 |
50 | 6.50 | 12.00 |
60 | 7.80 | 13.60 |
70 | 9.10 | 15.20 |
80 | 10.40 | 16.80 |
90 | 11.70 | 18.40 |
100 | 13.00 | 20.00 |
Request product information for a 0...13 ftH2O to 4...20 mA hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…4 mH2O to 0…10 V
Use this table to determine the exact calibration points for a 0…4 metres of water column range to 0…10 volts output hydrostatic liquid level sensor. For additional calibration points use our 0…4 mH2O to 0…10 V converter and enter any value.
% Scale | 0…4mH2O | 0…10V |
---|---|---|
0 | 0.00 | 0.00 |
10 | 0.40 | 1.00 |
20 | 0.80 | 2.00 |
30 | 1.20 | 3.00 |
40 | 1.60 | 4.00 |
50 | 2.00 | 5.00 |
60 | 2.40 | 6.00 |
70 | 2.80 | 7.00 |
80 | 3.20 | 8.00 |
90 | 3.60 | 9.00 |
100 | 4.00 | 10.00 |
Request product information for a 0...4 mH2O to 0...10 V hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…13 ftH2O to 0…10 V
Use this table to determine the exact calibration points for a 0…13 feet of water column range to 0…10 volts output hydrostatic liquid level sensor. For additional calibration points use our 0…13 ftH2O to 0…10 V converter and enter any value.
% Scale | 0…13ftH2O | 0…10V |
---|---|---|
0 | 0.00 | 0.00 |
10 | 1.30 | 1.00 |
20 | 2.60 | 2.00 |
30 | 3.90 | 3.00 |
40 | 5.20 | 4.00 |
50 | 6.50 | 5.00 |
60 | 7.80 | 6.00 |
70 | 9.10 | 7.00 |
80 | 10.40 | 8.00 |
90 | 11.70 | 9.00 |
100 | 13.00 | 10.00 |
Request product information for a 0...13 ftH2O to 0...10 V hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…4 mH2O to 0…5 V
Use this table to determine the exact calibration points for a 0…4 metres of water column range to 0…5 volts output hydrostatic liquid level sensor. For additional calibration points use our 0…4 mH2O to 0…5 V converter and enter any value.
% Scale | 0…4mH2O | 0…5V |
---|---|---|
0 | 0.00 | 0.00 |
10 | 0.40 | 0.50 |
20 | 0.80 | 1.00 |
30 | 1.20 | 1.50 |
40 | 1.60 | 2.00 |
50 | 2.00 | 2.50 |
60 | 2.40 | 3.00 |
70 | 2.80 | 3.50 |
80 | 3.20 | 4.00 |
90 | 3.60 | 4.50 |
100 | 4.00 | 5.00 |
Request product information for a 0...4 mH2O to 0...5 V hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…13 ftH2O to 0…5 V
Use this table to determine the exact calibration points for a 0…13 feet of water column range to 0…5 volts output hydrostatic liquid level sensor. For additional calibration points use our 0…13 ftH2O to 0…5 V converter and enter any value.
% Scale | 0…13ftH2O | 0…5V |
---|---|---|
0 | 0.00 | 0.00 |
10 | 1.30 | 0.50 |
20 | 2.60 | 1.00 |
30 | 3.90 | 1.50 |
40 | 5.20 | 2.00 |
50 | 6.50 | 2.50 |
60 | 7.80 | 3.00 |
70 | 9.10 | 3.50 |
80 | 10.40 | 4.00 |
90 | 11.70 | 4.50 |
100 | 13.00 | 5.00 |