0…10 mH2O or 0…33 ftH2O liquid level range, 4…20 mA, 0…10 V, or 0…5 V output signal hydrostatic liquid level sensors.
These hydrostatic liquid level sensors will measure from 0 to 10 metres of water column or 0 to 33 feet of water column liquid level ranges, and convert the measured level to a corresponding output signal from 4 to 20 milliamps, 0 to 10 volts, or 0 to 5 volts.
Sulfuric acid 12-15% conc. drop-in level probe for 10m high tank
40ft range 4-20mA output submersible hydroelectric dam headwater level sensor
Geothermal pool high temperature submersible level transmitter
10 metre high vegetable oil level transducer with 0 to 10 volt output
10m range high resolution 4-20mA out submersible freshwater tank level sensor
10 meter range submersible salt water level probe with current output
10mH2Og borehole monitoring 4-20mA output submersible water level sensor
Marine aquaculture submersible seawater level & temperature transmitter
Ground water monitoring 10mH2O g range 4-20mA out level sensor
Immersible sewage level transmitter for pressures up to 15 psi
10,000 mmH2O range 19mm dia borehole water level sensor
-5…+50degC temperature and 10m range level dual 4-20mA submersible borehole transmitter
10m high chemical tank 4-20mA output submersible PVC and ceramic protected liquid level sensor
1 bar submersible water depth sensor with 4 to 20mA output
Aquaculture submersible freshwater level & temperature transmitter
Calibration Tables
0…10 mH2O to 4…20 mA
Use this table to determine the exact calibration points for a 0…10 metres of water column range to 4…20 milliamps output hydrostatic liquid level sensor. For additional calibration points use our 0…10 mH2O to 4…20 mA converter and enter any value.
% Scale | 0…10mH2O | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 1.00 | 5.60 |
20 | 2.00 | 7.20 |
30 | 3.00 | 8.80 |
40 | 4.00 | 10.40 |
50 | 5.00 | 12.00 |
60 | 6.00 | 13.60 |
70 | 7.00 | 15.20 |
80 | 8.00 | 16.80 |
90 | 9.00 | 18.40 |
100 | 10.00 | 20.00 |
Request product information for a 0...10 mH2O to 4...20 mA hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…33 ftH2O to 4…20 mA
Use this table to determine the exact calibration points for a 0…33 feet of water column range to 4…20 milliamps output hydrostatic liquid level sensor. For additional calibration points use our 0…33 ftH2O to 4…20 mA converter and enter any value.
% Scale | 0…33ftH2O | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 3.30 | 5.60 |
20 | 6.60 | 7.20 |
30 | 9.90 | 8.80 |
40 | 13.20 | 10.40 |
50 | 16.50 | 12.00 |
60 | 19.80 | 13.60 |
70 | 23.10 | 15.20 |
80 | 26.40 | 16.80 |
90 | 29.70 | 18.40 |
100 | 33.00 | 20.00 |
Request product information for a 0...33 ftH2O to 4...20 mA hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…10 mH2O to 0…10 V
Use this table to determine the exact calibration points for a 0…10 metres of water column range to 0…10 volts output hydrostatic liquid level sensor. For additional calibration points use our 0…10 mH2O to 0…10 V converter and enter any value.
% Scale | 0…10mH2O | 0…10V |
---|---|---|
0 | 0.00 | 0.00 |
10 | 1.00 | 1.00 |
20 | 2.00 | 2.00 |
30 | 3.00 | 3.00 |
40 | 4.00 | 4.00 |
50 | 5.00 | 5.00 |
60 | 6.00 | 6.00 |
70 | 7.00 | 7.00 |
80 | 8.00 | 8.00 |
90 | 9.00 | 9.00 |
100 | 10.00 | 10.00 |
Request product information for a 0...10 mH2O to 0...10 V hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…33 ftH2O to 0…10 V
Use this table to determine the exact calibration points for a 0…33 feet of water column range to 0…10 volts output hydrostatic liquid level sensor. For additional calibration points use our 0…33 ftH2O to 0…10 V converter and enter any value.
% Scale | 0…33ftH2O | 0…10V |
---|---|---|
0 | 0.00 | 0.00 |
10 | 3.30 | 1.00 |
20 | 6.60 | 2.00 |
30 | 9.90 | 3.00 |
40 | 13.20 | 4.00 |
50 | 16.50 | 5.00 |
60 | 19.80 | 6.00 |
70 | 23.10 | 7.00 |
80 | 26.40 | 8.00 |
90 | 29.70 | 9.00 |
100 | 33.00 | 10.00 |
Request product information for a 0...33 ftH2O to 0...10 V hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…10 mH2O to 0…5 V
Use this table to determine the exact calibration points for a 0…10 metres of water column range to 0…5 volts output hydrostatic liquid level sensor. For additional calibration points use our 0…10 mH2O to 0…5 V converter and enter any value.
% Scale | 0…10mH2O | 0…5V |
---|---|---|
0 | 0.00 | 0.00 |
10 | 1.00 | 0.50 |
20 | 2.00 | 1.00 |
30 | 3.00 | 1.50 |
40 | 4.00 | 2.00 |
50 | 5.00 | 2.50 |
60 | 6.00 | 3.00 |
70 | 7.00 | 3.50 |
80 | 8.00 | 4.00 |
90 | 9.00 | 4.50 |
100 | 10.00 | 5.00 |
Request product information for a 0...10 mH2O to 0...5 V hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…33 ftH2O to 0…5 V
Use this table to determine the exact calibration points for a 0…33 feet of water column range to 0…5 volts output hydrostatic liquid level sensor. For additional calibration points use our 0…33 ftH2O to 0…5 V converter and enter any value.
% Scale | 0…33ftH2O | 0…5V |
---|---|---|
0 | 0.00 | 0.00 |
10 | 3.30 | 0.50 |
20 | 6.60 | 1.00 |
30 | 9.90 | 1.50 |
40 | 13.20 | 2.00 |
50 | 16.50 | 2.50 |
60 | 19.80 | 3.00 |
70 | 23.10 | 3.50 |
80 | 26.40 | 4.00 |
90 | 29.70 | 4.50 |
100 | 33.00 | 5.00 |
Request product information for a 0...33 ftH2O to 0...5 V hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.