• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
SensorsONE

SensorsONE

  • Products
  • Contact

10 mbar, 4 inH2O, 1000 Pa, 2.3 oz/in2 Range 4-20 mA Output Pressure Sensors

0…10 mbar, 0…4 inH2O, 0…1000 Pa, or 0…2.3 oz/in2 pressure range, 4…20 mA output signal pressure sensors.

These pressure sensors will measure from 0 to 10 millibars, 0 to 4 inches of water column, 0 to 1000 pascals, or 0 to 2.3 ounces per square inch pressure ranges, and convert the measured pressure to a corresponding output signal from 4 to 20 milliamps.

  • ATEX approved negative 10 mbar vacuum pressure transmitter
  • Solvent compatible +/-100mWG dp transmitter with PTFE seals
  • 4 inch water column range 4-20mA differential pressure sensor for liquids
  • Measuring HVAC plenum and sub-floor air pressure in data centers
  • Air Replacement Plant (ARP) 100 mm H2O differential pressure transmitter
  • Plenum chamber differential pressure transmitter with 100 mmWG range
  • 1000 pascal bidirectional range dry gas pressure transmitter
  • 100 mmWG negative gauge range vacuum sensor
  • 5 inH2O g range 4-20mA output air pressure sensor for air cleaning use
  • Under and Over pressure monitoring -10…+200 mb pressure transmitter

Contents

Toggle
  • Calibration Tables
    • 0…10 mbar to 4…20 mA
    • 0…4 inH2O to 4…20 mA
    • 0…1000 Pa to 4…20 mA
    • 0…2.3 oz/in2 to 4…20 mA

Calibration Tables

0…10 mbar to 4…20 mA

Use this table to determine the exact calibration points for a 0…10 millibars range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…10 mbar to 4…20 mA converter and enter any value.

% Scale 0…10mbar 4…20mA
0 0.00 4.00
10 1.00 5.60
20 2.00 7.20
30 3.00 8.80
40 4.00 10.40
50 5.00 12.00
60 6.00 13.60
70 7.00 15.20
80 8.00 16.80
90 9.00 18.40
100 10.00 20.00

Request product information for a 0...10 mbar to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.

0…4 inH2O to 4…20 mA

Use this table to determine the exact calibration points for a 0…4 inches of water column range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…4 inH2O to 4…20 mA converter and enter any value.

% Scale 0…4inH2O 4…20mA
0 0.00 4.00
10 0.40 5.60
20 0.80 7.20
30 1.20 8.80
40 1.60 10.40
50 2.00 12.00
60 2.40 13.60
70 2.80 15.20
80 3.20 16.80
90 3.60 18.40
100 4.00 20.00

Request product information for a 0...4 inH2O to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.

0…1000 Pa to 4…20 mA

Use this table to determine the exact calibration points for a 0…1000 pascals range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…1000 Pa to 4…20 mA converter and enter any value.

% Scale 0…1000Pa 4…20mA
0 0.00 4.00
10 100.00 5.60
20 200.00 7.20
30 300.00 8.80
40 400.00 10.40
50 500.00 12.00
60 600.00 13.60
70 700.00 15.20
80 800.00 16.80
90 900.00 18.40
100 1,000.00 20.00

Request product information for a 0...1000 Pa to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.

0…2.3 oz/in2 to 4…20 mA

Use this table to determine the exact calibration points for a 0…2.3 ounces per square inch range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…2.3 oz/in2 to 4…20 mA converter and enter any value.

% Scale 0…2.3oz/in2 4…20mA
0 0.00 4.00
10 0.23 5.60
20 0.46 7.20
30 0.69 8.80
40 0.92 10.40
50 1.15 12.00
60 1.38 13.60
70 1.61 15.20
80 1.84 16.80
90 2.07 18.40
100 2.30 20.00

Request product information for a 0...2.3 oz/in2 to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.

Primary Sidebar

Pressure Sensor Specifier

Specify a pressure sensor

Select your pressure sensor requirements

Pressure Sensor Calculator

Calculate errors and readings for a pressure sensor
Enter your parameters into this pressure sensor calculator to determine calibration errors, expected readings, and error tolerances

Pressure Sensor Technology Guide

Rating table for performance of different pressure sensor technology types

Compare performance of the most popular pressure sensor technology types and how they rate for different application requirements

Wirelessly Measure & Log 4-20mA

Use this battery powered wireless 4-20mA wireless transmitter to transmit readings to a receiver connected to USB, RS485, RS232, cellular network or analog output

Use this battery powered 4-20mA wireless transmitter to transmit readings to a receiver connected to USB, RS485, RS232, cellular network or analog output

Calibrate Low Pressure Measuring Devices

DPC controller and calibrator for calibrating low range air pressure sensors and instruments
DPC controller and calibrator for calibrating low range air pressure sensors and instruments

Products

  • Pressure
  • Level
  • Temperature
  • Interfacing
  • Datalogging
  • Calibration
  • Wireless

Product Enquiry

Send us your enquiry for a product associated with this 10 mbar, 4 inH2O, 1000 Pa, 2.3 oz/in2 Range 4-20 mA Output Pressure Sensors page, and get assistance with selecting a product for your application.

Email Your Enquiry

enquiries@sensorsone.com
By clicking "OK" or continuing to use this website you are providing your consent to use cookies as described in our Privacy Policy

© 2025 SensorsONE Ltd, all rights reserved

  • Home
  • Products
  • Tools
  • Legal
  • Contact