• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
SensorsONE

SensorsONE

  • Products
  • Tools
  • Contact

Pressure Sensor Calculator

Select Answer Mode
Operation
Performance Limits
Calibration Deviation
Calculate Pressure Sensor Parameters
Pressure [?]
Conversion [?]
Low Limit [?]
High Limit [?]
Output [?]
Accuracy [?]
Pressure Error [?]
Output Error [?]

Click save settings to reload page with unique web page address for bookmarking and sharing the current tool settings

✕ clear settings



Pressure sensor products
  • TPSA Precision High Pressure Transducer 700 bar, 10000 psi, 70 MPa Pressure Sensors, Transducers & Transmitters
  • ATEX Approved Pressure Transmitters
  • TPSA Precision High Pressure Transducer 0-5 Volts Output Pressure Transducers
  • DPS200 HVAC Differential Pressure Transmitter

Related Tools

  • DP Flow Transmitter Output Calculator
  • Pressure Sensing Errors Calculator
  • Pressure Sensor Calibration Error Calculator
  • Pressure Sensor Output Calculator
  • Pressure Transducer 0-10V Voltage Output Calculator
  • Pressure Transducer 0-5V Voltage Output Calculator
  • Pressure Transducer 0.5-4.5V Voltage Output Calculator
  • Pressure Transducer 1-5V Voltage Output Calculator
  • Pressure Transducer Millivolt (mV) Output Calculator
  • Pressure Transmitter 0-20mA Current Output Calculator

Contents

  • User Guide
    • Answer Modes
      • Operation
      • Performance Limits
      • Calibration Deviation
    • Parameters
      • Pressure
      • Conversion
      • Low Limit
      • High Limit
      • Output
      • Accuracy
      • Pressure Error
      • Output Error

User Guide

This multi-function tool can be easily adapted to calculate all the main parameters required by users when setting up, configuring and calibrating the different types of pressure sensors.

Answer Modes

Operation

These answer modes will help you determine the exact input pressure or output reading for an entered measurement based on the selected pressure range and output type corresponding to your pressure sensor. Since pressure sensors are mostly scaled in bar or psi, a pressure converter is also available to convert a pressure reading to alternative units.

As an example, this is how you would set-up the tool for determining the expected output reading from a -15 to 100 psi range with a 4 to 20 mA output pressure transmitter.

Performance Limits

These choices will help you convert the manufacturers performance specification into directly relatable values for pressure and output. Manufacturer’s mainly define performance characteristics as a proportion of range, pressure or output units, and these answer modes will allow you to convert linearity, hysteresis, repeatability, stability, zero and offset errors into a pressure uncertainty, output deviation or proportion of full scale.

To demonstrate how you would use this tool to compare the manufacturer’s stated performance with actual measurements, this is how you would configure the calculator to convert a 0.25% full scale accuracy to a pressure error for a -75 to +75 psi range pressure transducer.

Calibration Deviation

Use these answer modes when calibrating your pressure sensor to determine the deviation of the output from the ideal value for a particular calibration set-point, as a proportional error or in units of output or pressure.

If you were calibrating a 350 bar pressure transducer with a 0 to 33 millivolts output, this is what you would enter to determine the pressure error in millibars, if the output is 16.512 mV for a 50% calibration setpoint of 175 bar.

Pressure sensor products
  • DPS200 HVAC Differential Pressure Transmitter
  • ATEX Approved Pressure Transmitters
  • 33X High Accuracy Digital Output Pressure Sensor
  • DMP331P Hygienic Flush Pressure Transmitter

Parameters

Pressure

This is the pressure which is measured by the pressure sensor, you can either enter a value to see what output to expect from a pressure sensor or you can enter the value verified by a calibration reference and compare it to the actual output to determine the calibration error.

Conversion

Pressure sensors are often scaled in bar or psi measurement units, but used to measure pressure in other units. You can use this converter to check the value of any pressure value in other units.

Low Limit

This is lowest pressure which the sensor will measure, and is used to define the lower limit of the pressure range, that also corresponds to the lowest output value.

High Limit

This is highest pressure which the sensor will measure, and is used to define the upper limit of the pressure range, that also corresponds to the highest output value.

Output

This is what the pressure sensor sends out in the form of an analogue signal or digital reading.  The output will typically vary proportionally with the measurement range as a straight line, although there will be slight deviations due to the accuracy limitations of the pressure sensor.

Accuracy

This the proportion of the pressure sensor output range which represents the amount of deviation from a perfect measurement. It is used to define the specification limits of pressure sensors on manufacturers product data sheets and brochures, and also to calculate calibration errors. Accuracy is often expressed as a percentage of full scale for pressure sensors.

Pressure Error

This is the amount of pressure deviation from a perfectly accurate measurement, and represents the scope of uncertainty in the output of the pressure sensor, expressed in pressure units.

Output Error

This is the amount of output deviation from a perfectly accurate measurement, and represents the scope of uncertainty in the output of the pressure sensor.

Pressure sensor products
  • IMPLR Low Range All Stainless Steel OEM Pressure Sensor
  • Chemical Resistant Hydrostatic Liquid Level & Pressure Sensors
  • TPSA Precision High Pressure Transducer 700 bar, 10000 psi, 70 MPa Pressure Sensors, Transducers & Transmitters
  • Low Differential Pressure Transmitters Low Differential Pressure Transmitters

Primary Sidebar

Tool Sections

  • Area
  • Chemical Quantities
  • Circular Shapes
  • Density
  • Diameter & Radius
  • Electrical & Electromagnetic
  • Energy & Power
  • Flow
  • Force, Load & Torque
  • Health & Fitness
  • Length & Distance
  • Liquid Depth & Level
  • Mass & Weight
  • Movement & Motion
  • Pressure
  • Pricing & Quantities
  • Rectangular Shapes
  • Sensors & Instruments
  • Speed & Acceleration
  • Temperature & Heat
  • Time & Frequency
  • Travel & Transportation
  • Volumetric

Tool Feedback

Please provide feedback on using this Pressure Sensor Calculator.

Pressure Sensor Specifier

Specify a pressure sensor

Select your pressure sensor requirements

Measurement Instrument Specifier

Specify a measurement instrument

Select your measurement instrument requirements

Wirelessly Measure & Log Pressure

Use this battery powered wireless pressure sensor to transmit readings to a receiver connected to USB, RS485, RS232, cellular network or analog output

Use this battery powered wireless pressure sensor to transmit readings to a receiver connected to USB, RS485, RS232, cellular network or analog output

Pressure Sensor Types

  • 600 bar, 9000 psi, 60 MPa Pressure Sensors, Transducers & Transmitters
  • Steam Pressure Transmitters
  • 0-10 Volts Output Pressure Transducers
  • High Temperature Pressure Transmitters
  • Suction Pressure Transducers
  • HART® Pressure Transmitters

Product Selection Guides

  • Data Loggers
  • Differential Pressure Sensors
  • Digital Pressure Gauges
  • Digital Pressure Sensors
  • Digital Readouts
  • Hydrostatic Liquid Level Sensors
  • Liquid Level Sensors
  • Millivolt Output Pressure Transducers
  • Pressure Transducers
  • Pressure Transmitters
  • Voltage Output Pressure Transducers
By clicking "OK" or continuing to use this website you are providing your consent to use cookies as described in our Privacy Policy

© 2023 SensorsONE Ltd, all rights reserved

  • Home
  • Products
  • Tools
  • Legal
  • Contact