0…30 mH2O or 0…100 ftH2O liquid level range, 4…20 mA, 0…10 V, or 0…5 V output signal hydrostatic liquid level sensors.
These hydrostatic liquid level sensors will measure from 0 to 30 metres of water column or 0 to 100 feet of water column liquid level ranges, and convert the measured level to a corresponding output signal from 4 to 20 milliamps, 0 to 10 volts, or 0 to 5 volts.
- Water well 30mH2Og range 4-20mA out freshwater level sensor with RTD
- Ferric Chloride solution hydrostatic level transmitter
Calibration Tables
0…30 mH2O to 4…20 mA
Use this table to determine the exact calibration points for a 0…30 metres of water column range to 4…20 milliamps output hydrostatic liquid level sensor. For additional calibration points use our 0…30 mH2O to 4…20 mA converter and enter any value.
% Scale | 0…30mH2O | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 3.00 | 5.60 |
20 | 6.00 | 7.20 |
30 | 9.00 | 8.80 |
40 | 12.00 | 10.40 |
50 | 15.00 | 12.00 |
60 | 18.00 | 13.60 |
70 | 21.00 | 15.20 |
80 | 24.00 | 16.80 |
90 | 27.00 | 18.40 |
100 | 30.00 | 20.00 |
Request product information for a 0...30 mH2O to 4...20 mA hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…100 ftH2O to 4…20 mA
Use this table to determine the exact calibration points for a 0…100 feet of water column range to 4…20 milliamps output hydrostatic liquid level sensor. For additional calibration points use our 0…100 ftH2O to 4…20 mA converter and enter any value.
% Scale | 0…100ftH2O | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 10.00 | 5.60 |
20 | 20.00 | 7.20 |
30 | 30.00 | 8.80 |
40 | 40.00 | 10.40 |
50 | 50.00 | 12.00 |
60 | 60.00 | 13.60 |
70 | 70.00 | 15.20 |
80 | 80.00 | 16.80 |
90 | 90.00 | 18.40 |
100 | 100.00 | 20.00 |
Request product information for a 0...100 ftH2O to 4...20 mA hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…30 mH2O to 0…10 V
Use this table to determine the exact calibration points for a 0…30 metres of water column range to 0…10 volts output hydrostatic liquid level sensor. For additional calibration points use our 0…30 mH2O to 0…10 V converter and enter any value.
% Scale | 0…30mH2O | 0…10V |
---|---|---|
0 | 0.00 | 0.00 |
10 | 3.00 | 1.00 |
20 | 6.00 | 2.00 |
30 | 9.00 | 3.00 |
40 | 12.00 | 4.00 |
50 | 15.00 | 5.00 |
60 | 18.00 | 6.00 |
70 | 21.00 | 7.00 |
80 | 24.00 | 8.00 |
90 | 27.00 | 9.00 |
100 | 30.00 | 10.00 |
Request product information for a 0...30 mH2O to 0...10 V hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…100 ftH2O to 0…10 V
Use this table to determine the exact calibration points for a 0…100 feet of water column range to 0…10 volts output hydrostatic liquid level sensor. For additional calibration points use our 0…100 ftH2O to 0…10 V converter and enter any value.
% Scale | 0…100ftH2O | 0…10V |
---|---|---|
0 | 0.00 | 0.00 |
10 | 10.00 | 1.00 |
20 | 20.00 | 2.00 |
30 | 30.00 | 3.00 |
40 | 40.00 | 4.00 |
50 | 50.00 | 5.00 |
60 | 60.00 | 6.00 |
70 | 70.00 | 7.00 |
80 | 80.00 | 8.00 |
90 | 90.00 | 9.00 |
100 | 100.00 | 10.00 |
Request product information for a 0...100 ftH2O to 0...10 V hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…30 mH2O to 0…5 V
Use this table to determine the exact calibration points for a 0…30 metres of water column range to 0…5 volts output hydrostatic liquid level sensor. For additional calibration points use our 0…30 mH2O to 0…5 V converter and enter any value.
% Scale | 0…30mH2O | 0…5V |
---|---|---|
0 | 0.00 | 0.00 |
10 | 3.00 | 0.50 |
20 | 6.00 | 1.00 |
30 | 9.00 | 1.50 |
40 | 12.00 | 2.00 |
50 | 15.00 | 2.50 |
60 | 18.00 | 3.00 |
70 | 21.00 | 3.50 |
80 | 24.00 | 4.00 |
90 | 27.00 | 4.50 |
100 | 30.00 | 5.00 |
Request product information for a 0...30 mH2O to 0...5 V hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.
0…100 ftH2O to 0…5 V
Use this table to determine the exact calibration points for a 0…100 feet of water column range to 0…5 volts output hydrostatic liquid level sensor. For additional calibration points use our 0…100 ftH2O to 0…5 V converter and enter any value.
% Scale | 0…100ftH2O | 0…5V |
---|---|---|
0 | 0.00 | 0.00 |
10 | 10.00 | 0.50 |
20 | 20.00 | 1.00 |
30 | 30.00 | 1.50 |
40 | 40.00 | 2.00 |
50 | 50.00 | 2.50 |
60 | 60.00 | 3.00 |
70 | 70.00 | 3.50 |
80 | 80.00 | 4.00 |
90 | 90.00 | 4.50 |
100 | 100.00 | 5.00 |
Request product information for a 0...100 ftH2O to 0...5 V hydrostatic liquid level sensor that matches the input and output measurement range from the calibration table above.