These pressure sensors will measure from 0 to 250 millibars, 0 to 4 pounds per square inch, 0 to 100 inches of water column, or 0 to 25 kilopascals pressure ranges, and convert the measured pressure to a corresponding output signal from 4 to 20 milliamps.
Negative 250mbarg range 4-20mA out suction range pressure sensor
CIP cleaning low concentration acid solution pressure sensor with 100 inH2Og range and 4-20mA output
Calibration Tables
0…250 mbar to 4…20 mA
Use this table to determine the exact calibration points for a 0…250 millibars range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…250 mbar to 4…20 mA converter and enter any value.
% Scale | 0…250mbar | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 25.00 | 5.60 |
20 | 50.00 | 7.20 |
30 | 75.00 | 8.80 |
40 | 100.00 | 10.40 |
50 | 125.00 | 12.00 |
60 | 150.00 | 13.60 |
70 | 175.00 | 15.20 |
80 | 200.00 | 16.80 |
90 | 225.00 | 18.40 |
100 | 250.00 | 20.00 |
Request product information for a 0...250 mbar to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.
0…4 psi to 4…20 mA
Use this table to determine the exact calibration points for a 0…4 pounds per square inch range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…4 psi to 4…20 mA converter and enter any value.
% Scale | 0…4psi | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 0.40 | 5.60 |
20 | 0.80 | 7.20 |
30 | 1.20 | 8.80 |
40 | 1.60 | 10.40 |
50 | 2.00 | 12.00 |
60 | 2.40 | 13.60 |
70 | 2.80 | 15.20 |
80 | 3.20 | 16.80 |
90 | 3.60 | 18.40 |
100 | 4.00 | 20.00 |
Request product information for a 0...4 psi to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.
0…100 inH2O to 4…20 mA
Use this table to determine the exact calibration points for a 0…100 inches of water column range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…100 inH2O to 4…20 mA converter and enter any value.
% Scale | 0…100inH2O | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 10.00 | 5.60 |
20 | 20.00 | 7.20 |
30 | 30.00 | 8.80 |
40 | 40.00 | 10.40 |
50 | 50.00 | 12.00 |
60 | 60.00 | 13.60 |
70 | 70.00 | 15.20 |
80 | 80.00 | 16.80 |
90 | 90.00 | 18.40 |
100 | 100.00 | 20.00 |
Request product information for a 0...100 inH2O to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.
0…25 kPa to 4…20 mA
Use this table to determine the exact calibration points for a 0…25 kilopascals range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…25 kPa to 4…20 mA converter and enter any value.
% Scale | 0…25kPa | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 2.50 | 5.60 |
20 | 5.00 | 7.20 |
30 | 7.50 | 8.80 |
40 | 10.00 | 10.40 |
50 | 12.50 | 12.00 |
60 | 15.00 | 13.60 |
70 | 17.50 | 15.20 |
80 | 20.00 | 16.80 |
90 | 22.50 | 18.40 |
100 | 25.00 | 20.00 |
Request product information for a 0...25 kPa to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.