0…250 mbar, 0…4 psi, 0…100 inH2O, or 0…25 kPa pressure range, 4…20 mA output signal pressure sensors.

These pressure sensors will measure from 0 to 250 millibars, 0 to 4 pounds per square inch, 0 to 100 inches of water column, or 0 to 25 kilopascals pressure ranges, and convert the measured pressure to a corresponding output signal from 4 to 20 milliamps.

  • Tumbling pharmaceutical powder totes wireless pressure monitoring
  • Negative 250mbarg range 4-20mA out suction range pressure sensor
  • CIP cleaning low concentration acid solution pressure sensor with 100 inH2Og range and 4-20mA output

Contents

Toggle
  • Calibration Tables
    • 0…250 mbar to 4…20 mA
    • 0…4 psi to 4…20 mA
    • 0…100 inH2O to 4…20 mA
    • 0…25 kPa to 4…20 mA

Calibration Tables

0…250 mbar to 4…20 mA

Use this table to determine the exact calibration points for a 0…250 millibars range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…250 mbar to 4…20 mA converter and enter any value.

% Scale 0…250mbar 4…20mA
0 0.00 4.00
10 25.00 5.60
20 50.00 7.20
30 75.00 8.80
40 100.00 10.40
50 125.00 12.00
60 150.00 13.60
70 175.00 15.20
80 200.00 16.80
90 225.00 18.40
100 250.00 20.00

Request product information for a 0...250 mbar to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.

0…4 psi to 4…20 mA

Use this table to determine the exact calibration points for a 0…4 pounds per square inch range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…4 psi to 4…20 mA converter and enter any value.

% Scale 0…4psi 4…20mA
0 0.00 4.00
10 0.40 5.60
20 0.80 7.20
30 1.20 8.80
40 1.60 10.40
50 2.00 12.00
60 2.40 13.60
70 2.80 15.20
80 3.20 16.80
90 3.60 18.40
100 4.00 20.00

Request product information for a 0...4 psi to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.

0…100 inH2O to 4…20 mA

Use this table to determine the exact calibration points for a 0…100 inches of water column range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…100 inH2O to 4…20 mA converter and enter any value.

% Scale 0…100inH2O 4…20mA
0 0.00 4.00
10 10.00 5.60
20 20.00 7.20
30 30.00 8.80
40 40.00 10.40
50 50.00 12.00
60 60.00 13.60
70 70.00 15.20
80 80.00 16.80
90 90.00 18.40
100 100.00 20.00

Request product information for a 0...100 inH2O to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.

0…25 kPa to 4…20 mA

Use this table to determine the exact calibration points for a 0…25 kilopascals range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…25 kPa to 4…20 mA converter and enter any value.

% Scale 0…25kPa 4…20mA
0 0.00 4.00
10 2.50 5.60
20 5.00 7.20
30 7.50 8.80
40 10.00 10.40
50 12.50 12.00
60 15.00 13.60
70 17.50 15.20
80 20.00 16.80
90 22.50 18.40
100 25.00 20.00

Request product information for a 0...25 kPa to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.

Primary Sidebar

Pressure Sensor Specifier

Specify a pressure sensor

Select your pressure sensor requirements

Pressure Sensor Calculator

Calculate errors and readings for a pressure sensor
Enter your parameters into this pressure sensor calculator to determine calibration errors, expected readings, and error tolerances

Pressure Sensor Technology Guide

Rating table for performance of different pressure sensor technology types

Compare performance of the most popular pressure sensor technology types and how they rate for different application requirements

Wirelessly Measure & Log 4-20mA

Use this battery powered wireless 4-20mA wireless transmitter to transmit readings to a receiver connected to USB, RS485, RS232, cellular network or analog output

Use this battery powered 4-20mA wireless transmitter to transmit readings to a receiver connected to USB, RS485, RS232, cellular network or analog output

Calibrate Low Pressure Measuring Devices

DPC controller and calibrator for calibrating low range air pressure sensors and instruments
DPC controller and calibrator for calibrating low range air pressure sensors and instruments

Products

  • Pressure
  • Level
  • Temperature
  • Interfacing
  • Datalogging
  • Calibration
  • Wireless

Product Enquiry

Send us your enquiry for a product associated with this 250 mbar, 4 psi, 100 inH2O, 25 kPa Range 4-20 mA Output Pressure Sensors page, and get assistance with selecting a product for your application.

Email Your Enquiry

enquiries@sensorsone.com
By clicking "OK" or continuing to use this website you are providing your consent to use cookies as described in our Privacy Policy

© 2025 SensorsONE Ltd, all rights reserved

  • Home
  • Products
  • Tools
  • Legal
  • Contact