10 bar water mains pressure sensor with overpressure protection for commercial buildings

Request Price

This IMP water pressure sensor is specifically designed for monitoring incoming mains water pressure in commercial and industrial buildings. It features a 20 bar sensor element to provide enhanced overpressure protection, safeguarding the sensor from potential damage caused by pressure surges and spikes that can occur in water mains supplies.

The sensor’s construction incorporates several key features that ensure its suitability for this application:

  • 316 Stainless Steel Wetted Parts: The sensor’s wetted parts, including the 1/4 BSP male process connection, are constructed from 316 stainless steel. This material offers excellent corrosion resistance, ensuring the sensor’s long-term performance in the presence of fresh water.
  • EPDM Internal Seals: EPDM (ethylene propylene diene monomer) seals are used internally within the sensor. EPDM is an elastomer known for its resistance to water, making it an ideal choice for this application.
  • Ceramic Diaphragm: The sensor utilizes a ceramic diaphragm, which is chemically inert. This means it will not react with the fresh water being measured, ensuring the accuracy and stability of the sensor readings over time.

This particular configuration of the IMP sensor is factory calibrated and temperature compensated, ensuring accurate and reliable pressure measurement over a wide range of operating conditions. The sensor provides a 0-10V output signal, allowing for easy integration with various monitoring and control systems commonly used in building management systems (BMS) or industrial automation systems.

The use of a 20 bar sensor element in this 10 bar range sensor is a notable feature. While the sensor is intended to measure pressures up to 10 bar, the 20 bar element provides a significant safety margin. This overpressure capability protects the sensor from damage in the event of unexpected pressure spikes, ensuring its continued operation and preventing costly downtime or replacement.

This sensor is ideal for applications such as:

  • Monitoring water pressure at the main entry point of a building
  • Ensuring adequate water pressure for fire suppression systems
  • Monitoring water pressure in industrial processes that rely on a consistent water supply
  • Detecting leaks or other anomalies in the water supply system

By providing accurate and reliable pressure measurement, this sensor contributes to the efficient operation and maintenance of water systems in commercial and industrial settings. Its robust design and overpressure protection ensure long-term reliability, even in demanding environments.

10 bar incoming mains water pressure sensor

IMP Mains Water Pressure Sensor

  • Part No: IMP-C0043-7A4-BBE-000
  • Datum: Sealed Gauge
  • Pressure Range: 10 bar sealed gauge
  • Output: 0 – 10V, 3-wire (7)
  • Non-Linearity and Hysteresis: 0.25% FS (standard) (A)
  • Thermal Zero Shift: 0.04% FS per °C (standard) (4)
  • Electrical Connection: Large Plug & Socket, GDM3009, DIN43650 (B)
  • Process Connection: G 1/4 male DIN 3852, 316 St/St (B)
  • Internal Seal Material: EPDM (E)
  • Special Requirements: Use 20 bar sensor element

Request Product Price

"*" indicates required fields

Please complete form below to request a quote for 10 bar water mains pressure sensor with overpressure protection for commercial buildings.

Please enter info about your application and include any other requirements.

⚠ Attention Required

Please remove all web links from Application Details text entry box above, to enable form submission.

You will be able to provide any links related to your enquiry later on, by replying to the email confirmation once your submission has been processed.

Thank you.



Primary Sidebar

Pressure Sensor Specifier

Specify a pressure sensor

Select your pressure sensor requirements

Pressure Sensor Calculator

Calculate errors and readings for a pressure sensor
Enter your parameters into this pressure sensor calculator to determine calibration errors, expected readings, and error tolerances

Pressure Sensor Technology Guide

Rating table for performance of different pressure sensor technology types

Compare performance of the most popular pressure sensor technology types and how they rate for different application requirements

Wirelessly Measure & Log 0-10Vdc

Use this battery powered 0-10Vdc wireless transmitter to transmit readings to a receiver connected to USB, RS485, RS232, cellular network or analog output

Use this battery powered 0-10Vdc wireless transmitter to transmit readings to a receiver connected to USB, RS485, RS232, cellular network or analog output

Products

  • Pressure
  • Level
  • Temperature
  • Interfacing
  • Datalogging
  • Calibration
  • Wireless

Product Enquiry

Send us your enquiry for 10 bar water mains pressure sensor with overpressure protection for commercial buildings to get assistance with this product type.

Email Your Enquiry

enquiries@sensorsone.com
By clicking "OK" or continuing to use this website you are providing your consent to use cookies as described in our Privacy Policy

© 2025 SensorsONE Ltd, all rights reserved

  • Home
  • Products
  • Tools
  • Legal
  • Contact