ADT901 low pressure calibration pumpThe ADT901 low pressure calibration pump is a hand operated pressure pump designed to generate pressures from -6 psi (-0.4 bar) to 6 psi (0.4 bar).

A high-quality screw press is designed for fine pressure adjustment, with an adjustment resolution as high as 0.01 Pa (0.0001 mbar).

ADT901 low pressure calibration pump with test gauge and DUT

To make pressure setting as stable as possible during micro-pressure calibrations, an isothermal bellows chamber has been incorporated into the design for reducing the heating and cooling effects caused by environmental temperature change.

There is no non-return valve fitted which is usually used on other types of hand pumps, therefore the ADT-901 requires minimal maintenance.

Two hand-tight connectors fitted to the pump provide easy connecting and disconnecting to the test pump without the need for PTFE tape or spanners. The ADT 901 is an ideal comparison test pump for low pressure applications.

Contents

  • Features
      • Portable
      • High resolution
      • Good stability
      • Durable and minimal maintenance
      • Easy to use
      • Handtight connectors
  • Applications
  • Specifications
      • Media
      • Generated Pressure Range
      • Pressure Resolution
      • Material
      • Connection
      • Dimensions
      • Weight
  • Part Numbers
  • Accessories
  • Component Functions
  • Pneumatic Layout
  • Operation Guide
  • Related Documents

Features

Portable

Only 3.5 lb

High resolution

0.01Pa (0.0001 mbar) Specially designed screw press for fine pressure adjustment

Good stability

Isothermal chamber: the pressure chamber is insulated to reduce the influence of environmental temperature changes.

Specially designed bellows reduces leakage to guarantee excellent stability.

Durable and minimal maintenance

Without non-returning valve that is usually used on trouble some hand pump.

Easy to use

Pressure could be set and adjusted precisely and quickly through a simple turn of the handle.

Handtight connectors

Allows easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches.

Applications

ADT901 low pressure calibration pump with test gauge and process transmitterThe ADT901 low pressure calibration pump is designed for low pressure applications requiring precise testing and calibration. You can use this pump for calibrating low pressure gauges, switches, shut-off valves, transmitters or any other low range pressure measuring instruments.

Specifications

Media

  • Air

Generated Pressure Range

  • -6 psi (-0.4 bar) to 6 psi (0.4 bar) pressure

Pressure Resolution

  • 0.01 Pa (0.0001 mbar)

Material

  • Ram/Adapters: Stainless steel
  • Body: Stainless steel/Aluminum
  • Seals: Buna-N

Connection

Hand-tight connectors for both test gauge and reference gauge

  • Test Gauge connection: 1/4NPT female, 1/4BSP female, or M20X1.5 female
  • Reference Gauge Connection: 1/4NPT female, 1/4BSP female, or M20X1.5 female

Dimensions

  • Height: 5.7” (145 mm)
  • Base: 9.65” (245 mm) x 6.50” (165 mm)

Weight

  • 3.5 lb (1.6 kg)

Part Numbers

ADT901 Part No Coding

Accessories

ADT901 Optional Extras

Component Functions

ADT901 low pressure test pump component functions

Pneumatic Layout

ADT901 low pressure test pump pneumatic schematic diagram

Operation Guide

ADT901 low pressure test pump basic operation guide

Related Documents

  • ADT901 data sheet

Request Product Price

  • Please complete this form to request a quote for +/- 6 psi / 0.4 bar Low Pressure Calibration Pump - ADT901

  • Please enter info about your required product specification and type of application, plus any other requirements.

  • ⚠ Attention Required

    Please remove all web links from Product and Application Requirements text entry box above, to enable form submission.

    You will be able to provide any links related to your enquiry later on, by replying to the email confirmation once your submission has been processed.

    Thank you.



Primary Sidebar

Product Selection Guides

  • Pressure Transmitters
  • Pressure Transducers
  • Liquid Level Sensors
  • Hydrostatic Liquid Level Sensors
  • Digital Pressure Sensors
  • Digital Pressure Gauges
  • Differential Pressure Sensors

Application Selection Guides

  • Vacuum
  • Submersible
  • Oxygen Service
  • Flush Diaphragm
  • Dual Temperature and Pressure
  • Differential Pressure

Help Guides

  • What is the difference between gauge and absolute pressure measurement
  • Using Hydrostatic Pressure Transducers for Measuring Fluid Level
  • Using absolute pressure sensors to measure hydrostatic level
  • Measuring vacuum with negative gauge or absolute ranges
  • Measuring the difference in air pressure between rooms
  • Measuring liquid level in a sealed tank with a hydrostatic pressure sensor
  • How do you measure flow rate with a dp cell
  • Determining water tank volume using hydrostatic pressure
  • ATEX Classifications Glossary for products used in Explosive Atmospheres

Online Measurement Tools

  • Vertical Cylindrical Shaped Tank Contents Calculator
  • Total Volume & Total Time to Flow Rate Calculator
  • Temperature Transmitter 4-20mA Current Output Calculator
  • Pressure Transmitter 4-20mA Current Output Calculator
  • Pressure to Liquid Level Calculator
  • Pressure Converter
  • Pressure & Area to Force Calculator
  • Piston Cylinder Pressure & Diameter to Force Calculator
  • Measurement Reading to 4-20mA Signal Converter
  • Liquid Level Transmitter 4-20mA Current Output Calculator
  • Liquid Depth/Level to Hydrostatic Pressure Calculator
  • Input to Output Measurement Reading Converter
  • Horizontal Cylindrical Shaped Tank Contents Calculator
  • Force & Area to Pressure Calculator
  • Density to Specific Gravity Calculator
  • Calibration Error Calculator
  • 4-20mA Signal to Measurement Reading Converter

Product Enquiry

Send us your enquiry for +/- 6 psi / 0.4 bar Low Pressure Calibration Pump – ADT901 to get assistance with this product type.

Email Your Enquiry

enquiries@sensorsone.com

Footer

By clicking "OK" or continuing to use this website you are providing your consent to use cookies as described in our Privacy Policy

© 2021 SensorsONE Ltd, all rights reserved

  • Home
  • Legal
  • Contact