0…500 mbar, 0…7.5 psi, 0…200 inH2O, or 0…50 kPa pressure range, 4…20 mA output signal pressure sensors.
These pressure sensors will measure from 0 to 500 millibars, 0 to 7.5 pounds per square inch, 0 to 200 inches of water column, or 0 to 50 kilopascals pressure ranges, and convert the measured pressure to a corresponding output signal from 4 to 20 milliamps.
Hastelloy diaphragm -100 to 50 kPa g range manometer
500 mbar vacuum sensor for use on fresh water with 4 to 20 milliamp output
Compound vacuum and pressure HART transmitter for +/- 500 mmWG
Vacuum conveyor pressure transmitter with minus 500 mbar range
500mbarg range 4-20mA signal stainless steel pressure sensor
50 kPa negative gauge vacuum transmitter for Milk
Calibration Tables
0…500 mbar to 4…20 mA
Use this table to determine the exact calibration points for a 0…500 millibars range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…500 mbar to 4…20 mA converter and enter any value.
% Scale | 0…500mbar | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 50.00 | 5.60 |
20 | 100.00 | 7.20 |
30 | 150.00 | 8.80 |
40 | 200.00 | 10.40 |
50 | 250.00 | 12.00 |
60 | 300.00 | 13.60 |
70 | 350.00 | 15.20 |
80 | 400.00 | 16.80 |
90 | 450.00 | 18.40 |
100 | 500.00 | 20.00 |
Request product information for a 0...500 mbar to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.
0…7.5 psi to 4…20 mA
Use this table to determine the exact calibration points for a 0…7.5 pounds per square inch range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…7.5 psi to 4…20 mA converter and enter any value.
% Scale | 0…7.5psi | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 0.75 | 5.60 |
20 | 1.50 | 7.20 |
30 | 2.25 | 8.80 |
40 | 3.00 | 10.40 |
50 | 3.75 | 12.00 |
60 | 4.50 | 13.60 |
70 | 5.25 | 15.20 |
80 | 6.00 | 16.80 |
90 | 6.75 | 18.40 |
100 | 7.50 | 20.00 |
Request product information for a 0...7.5 psi to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.
0…200 inH2O to 4…20 mA
Use this table to determine the exact calibration points for a 0…200 inches of water column range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…200 inH2O to 4…20 mA converter and enter any value.
% Scale | 0…200inH2O | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 20.00 | 5.60 |
20 | 40.00 | 7.20 |
30 | 60.00 | 8.80 |
40 | 80.00 | 10.40 |
50 | 100.00 | 12.00 |
60 | 120.00 | 13.60 |
70 | 140.00 | 15.20 |
80 | 160.00 | 16.80 |
90 | 180.00 | 18.40 |
100 | 200.00 | 20.00 |
Request product information for a 0...200 inH2O to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.
0…50 kPa to 4…20 mA
Use this table to determine the exact calibration points for a 0…50 kilopascals range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…50 kPa to 4…20 mA converter and enter any value.
% Scale | 0…50kPa | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 5.00 | 5.60 |
20 | 10.00 | 7.20 |
30 | 15.00 | 8.80 |
40 | 20.00 | 10.40 |
50 | 25.00 | 12.00 |
60 | 30.00 | 13.60 |
70 | 35.00 | 15.20 |
80 | 40.00 | 16.80 |
90 | 45.00 | 18.40 |
100 | 50.00 | 20.00 |
Request product information for a 0...50 kPa to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.