• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to footer
SensorsONE

SensorsONE

Measurement Instrumentation Products

  • Products
  • Tools
  • Contact

32…212°F Temperature Range Sensor with 4-20mA Current Output Signal Transmitter

Measure temperature over a 32 to 212 degrees Fahrenheit range and convert it to a 4 to 20 milliamps loop output signal.

32...212°F Temperature Range Sensor with 4-20mA Current Output Signal Transmitter

Contents

  • Products
    • STT-26 32…212°F IP68 Temperature Probe & Transmitter
      • STT-26 32…212°F IP68 Freshwater Thermometer & Transmitter
      • STT-26 32…212°F IP68 Seawater Thermometer & Transmitter
  • Conversion Tool and Table

Products

STT-26 32…212°F IP68 Temperature Probe & Transmitter

STT-26 32...212°F IP68 Temperature Probe & TransmitterThe STT-26 submersible temperature probe is used to measure temperature in a liquid over a 32 to 212 degF range, using a submerged PT100 thermometer, and an integrated 4-20mA current loop output transmitter to send the signal through long cable lengths.

STT-26 32…212°F IP68 Freshwater Thermometer & Transmitter

  • SKU ID: s1-stt26-0003
  • Part Number: STT-26-SP-005-E-00
  • Housing Material: Stainless Steel 316
  • Cable Material: PUR
  • Cable Length: 5 metres (16 feet)
  • Pressure Rating: Tested to 5 bar, 72.5 psi, 50mH2O, 167 ftH2O for 48 hours
  • Sensor Technology: PT100 – Platinum Resistance Thermometer
  • Calibrated Temperature Range: 32…212°F
  • Output Signal: 4-20mA, 2 wire current loop
  • Accuracy: mA out/2000 or 5 uA, whichever is the greater
  • Power Supply: 10-32Vdc
  • Special Options: None

STT-26 32…212°F IP68 Seawater Thermometer & Transmitter

  • SKU ID: s1-stt26-0004
  • Part Number: STT-26-MT-005-E-00
  • Housing Material: Marine Bronze CA104
  • Cable Material: TPE-U
  • Cable Length: 5 metres (16 feet)
  • Pressure Rating: Tested to 5 bar, 72.5 psi, 50mH2O, 167 ftH2O for 48 hours
  • Sensor Technology: PT100 – Platinum Resistance Thermometer
  • Calibrated Temperature Range: 32…212°F
  • Output Signal: 4-20mA, 2 wire current loop
  • Accuracy: mA out/2000 or 5 uA, whichever is the greater
  • Power Supply: 10-32Vdc
  • Special Options: None

Conversion Tool and Table

Enter or look up a measured temperature over the range 32 to 212 degrees Fahrenheit to determine the current reading from a 4 to 20 mA output signal transmitter.

Enter input value in °F for a linear range from 32 to 212 °F to calculate output value in mA for a linear range from 4 to 20 mA.

Input °F
Output mA
Sorry, a graphic could not be displayed here, because your browser does not support HTML5 Canvas.

Request product info for a 32...212 °F linear input range to 4...20 mA linear output scale measurement device.

Pick a value from the 32 to 212 °F linear input range column of the conversion table below, and find the corresponding value in the 4 to 20 mA linear output range column.

32...212 °F 4...20 mA 🔗

Primary Sidebar

Tool Sections

  • Density
  • Flow
  • Energy & Power
  • Electrical & Electromagnetic
  • Force, Load & Torque
  • Input & Output Signals
  • Length, Area & Volume
  • Liquid Depth & Level
  • Mass & Weight
  • Pressure
  • Speed & Acceleration
  • Temperature
  • Time & Frequency

Email Your Enquiry

enquiries@sensorsone.com

Product Enquiry

Send us your enquiry for a product associated with this 32…212°F Temperature Range Sensor with 4-20mA Current Output Signal Transmitter page, and get assistance with selecting a product for your application.

Measure Temperature In A Liquid

Submerge this STT-26 Probe to measure the temperature of a liquid and transmit a 4-20mA current loop output signal.
Submerge this STT-26 Probe to measure the temperature of a liquid and transmit a 4-20mA current loop output signal.

Product Selection Guides

  • Voltage Output Pressure Transducers
  • Pressure Transmitters
  • Pressure Transducers
  • Millivolt Output Pressure Transducers
  • Hydrostatic Liquid Level Sensors
  • Digital Pressure Sensors
  • Digital Pressure Gauges
  • Differential Pressure Sensors
  • Data Loggers

Application Selection Guides

  • Vacuum
  • Submersible
  • Low Pressure Range
  • Leak Testing
  • High Frequency Response
  • Dual Temperature and Pressure
  • Barometric Pressure

Help Guides

  • Reduce calibration costs of analogue pressure gauges
  • Measuring the difference in air pressure between rooms
  • How to get a 10 volt signal from a 4-20mA output pressure sensor
  • How to Connect a 4-20mA Current Loop Pressure Transmitter
  • Determining the hydrostatic pressure range for a tank level sensor
  • Choosing PVC, PUR, FEP and TPE cable types

Online Measurement Tools

  • Temperature Transmitter 4-20mA Current Output Calculator
  • Pressure Transmitter 4-20mA Current Output Calculator
  • Pressure Transducer 1-5V Voltage Output Calculator
  • Pressure Converter
  • Measurement Reading to 4-20mA Signal Converter
  • Liquid Depth/Level to Hydrostatic Pressure Calculator
  • Input to Output Measurement Reading Converter
  • Force & Area to Pressure Calculator
  • Density to Specific Gravity Calculator

Footer

By clicking "OK" or continuing to use this website you are providing your consent to use cookies as described in our Privacy Policy

© 2021 SensorsONE Ltd, all rights reserved

  • Home
  • Legal
  • Contact