0…200 bar, 0…3000 psi, 0…200 kg/cm2, or 0…20 MPa pressure range, 4…20 mA output signal pressure sensors.
These pressure sensors will measure from 0 to 200 bars, 0 to 3000 pounds per square inch, 0 to 200 kilograms per square centimetre, or 0 to 20 megapascals pressure ranges, and convert the measured pressure to a corresponding output signal from 4 to 20 milliamps.
Alternative 200 bar melt pressure transmitter with T/C
20 MPa g range 4-20mA output high pressure sensor and plug-on display for hydraulic control use
3000 psig hydraulic press machine 4-20mA pressure sensor
Agricultural machinery hydraulic control pressure sensor with 200 barg rang and 0-10Vdc out
Calibration Tables
0…200 bar to 4…20 mA
Use this table to determine the exact calibration points for a 0…200 bars range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…200 bar to 4…20 mA converter and enter any value.
% Scale | 0…200bar | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 20.00 | 5.60 |
20 | 40.00 | 7.20 |
30 | 60.00 | 8.80 |
40 | 80.00 | 10.40 |
50 | 100.00 | 12.00 |
60 | 120.00 | 13.60 |
70 | 140.00 | 15.20 |
80 | 160.00 | 16.80 |
90 | 180.00 | 18.40 |
100 | 200.00 | 20.00 |
Request product information for a 0...200 bar to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.
0…3000 psi to 4…20 mA
Use this table to determine the exact calibration points for a 0…3000 pounds per square inch range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…3000 psi to 4…20 mA converter and enter any value.
% Scale | 0…3000psi | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 300.00 | 5.60 |
20 | 600.00 | 7.20 |
30 | 900.00 | 8.80 |
40 | 1,200.00 | 10.40 |
50 | 1,500.00 | 12.00 |
60 | 1,800.00 | 13.60 |
70 | 2,100.00 | 15.20 |
80 | 2,400.00 | 16.80 |
90 | 2,700.00 | 18.40 |
100 | 3,000.00 | 20.00 |
Request product information for a 0...3000 psi to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.
0…200 kg/cm2 to 4…20 mA
Use this table to determine the exact calibration points for a 0…200 kilograms per square centimetre range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…200 kg/cm2 to 4…20 mA converter and enter any value.
% Scale | 0…200kg/cm2 | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 20.00 | 5.60 |
20 | 40.00 | 7.20 |
30 | 60.00 | 8.80 |
40 | 80.00 | 10.40 |
50 | 100.00 | 12.00 |
60 | 120.00 | 13.60 |
70 | 140.00 | 15.20 |
80 | 160.00 | 16.80 |
90 | 180.00 | 18.40 |
100 | 200.00 | 20.00 |
Request product information for a 0...200 kg/cm2 to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.
0…20 MPa to 4…20 mA
Use this table to determine the exact calibration points for a 0…20 megapascals range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…20 MPa to 4…20 mA converter and enter any value.
% Scale | 0…20MPa | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 2.00 | 5.60 |
20 | 4.00 | 7.20 |
30 | 6.00 | 8.80 |
40 | 8.00 | 10.40 |
50 | 10.00 | 12.00 |
60 | 12.00 | 13.60 |
70 | 14.00 | 15.20 |
80 | 16.00 | 16.80 |
90 | 18.00 | 18.40 |
100 | 20.00 | 20.00 |
Request product information for a 0...20 MPa to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.