I’m looking for a loop powered pressure indicator that I can mount in a hazardous (Zone 1) location to read a pressure transducer that is remotely located from the indicator. The wet connection on the transducer should be a WECO® 1502.
We would suggest a PA440 loop powered display which can mounted on a wall in the hazardous area connected to a HU300 which is a pressure transmitter with a hammer union WECO® 1502 process connection.
HU300 Hammer Union Pressure Transmitter
- HU300 data sheet
- Pressure Range: 5000
- Pressure Unit: psi
- Reference Pressure: Gauge (g)
- Output Signal: 4 to 20 mA,2-wire, intrinsic safety
- Process Connection: WECO® 2″ 1502
- Electrical Termination: Cable outlet IP 68 with FEP cable
- Intrinsically Safe / ATEX: Yes
PA440 Loop Powered Indicator for Wall Mounting
- PA440 data sheet
- Analogue Output: 4-20mA, ATEX IS, (2 wire)
- Display: LCD
- Housing Material: Plastic ABS
- Switch Contacts: Not required
- Electrical Connection: Cable gland M16x1.5
- Engineering Unit Label: Fitted by user