This multi-function tool can be easily adapted to calculate all the main parameters required by users when setting up, configuring and calibrating the different types of temperature sensors with added signal conditioning.
Measurement Signal
Measurement signal related guides and product information for handling the input and output signals of digital and analogue measurement instrumentation
SDI-12 Serial Interface Sensors and Instruments
Instrumentation with a serial data interface with a baud rate of 1200 for connecting to environmental data acquisition (EDA) products.
I²C Serial Interface Sensors and Instruments
Instrumentation that has a I²C (Inter-Integrated Circuit) serial computer bus interface for inter-connection & compatibility with other I²C components.
4-20mA Max. Load Resistance, Min. Tx and Power Supply Calculator
This tool will calculate the maximum load resistance, minimum power supply or transmitter supply that can be used, in order for a 4 to 20mA current loop circuit to have sufficient power to operate.
4-20mA Signal, Shunt Resistor and Volts Out Calculator
This tool will calculate the voltage drop created by adding a shunt resistor to a 4-20mA current loop signal circuit
Pressure Sensor Calibration Error Calculator
Use this tool to calculate the output error of a pressure sensor by entering the calibration reference pressure reading, pressure sensor range and measured output.
Pressure Sensor Output Calculator
This tool will calculate the expected output signal from a pressure sensor of a certain specified pressure range and applied pressure. It is also possible to reverse the function of the tool to calculate the applied pressure expected to produce a specific output reading.
4 to 20 mA Supply, Load, Shunt and Signal Calculator
This 4-20mA current loop signal circuit tool will calculate all the electrical parameters associated with the power supply, load resistance, transmitter supply, shunt voltage drop and current signal.
Pressure Sensor Calculator
This multi-function tool can be easily adapted to calculate all the main parameters required by users when setting up, configuring and calibrating the different types of pressure sensors.
0-70mV to 4-20mA Signal Conversion
Convert a 0 to 70 millivolts range measurement input signal into a 4 to 20 milliamps loop output signal.
0-5V to 0-6.5V Signal Conversion
Convert a 0 to 5 volts range measurement input signal into a 0 to 6.5 volts output signal.
0-12V to 0-5V Signal Conversion
Convert a 0 to 12 volt range measurement input signal into a 0 to 5 volts output signal.
IWCTT Current Transformer mV ac Signal Input to Wireless Transmitter
Measure the millivolt alternating current output from any split core current transformer and wirelessly transmit it to a wireless receiver hub
IWDigT Switch or Pulse Input to Wireless Transmitter
Measure the open and closing of any voltage free contact switch or a pulses from a counter input, and wirelessly transmit it to a wireless receiver hub
IWVT 0-10Vdc Signal Input to Wireless Transmitter
Measure the signal from any 0 to 10 volt output measurement device, and wirelessly transmit it to a wireless receiver hub
IWmAT 4-20mA Signal Input to Wireless Transmitter
Measure the current loop signal output from any 4 to 20 milliamp transmitter, and wirelessly transmit it to a wireless receiver hub
IWTxT Loop Powered 4-20mA Input to Wireless Transmitter
Power and measure the current loop signal output from any 4 to 20 milliamp transmitter, and wirelessly transmit it to a wireless receiver hub
Pressure Transmitter 0-20mA Current Output Calculator
This pressure transmitter 0 to 20 milliamp current output calculator provides a way to determine the output reading from the applied pressure and pressure transmitter range.
4-20mA Output Pressure Sensors
Choose from an extensive range of pressure with a 4 to 20 milliamp current output signal.
Output signal orientation for a negative gauge pressure range
Since a negative pressure range works backwards to a positive gauge or an absolute pressure range, and that zero pressure corresponds to a full scale measurement, it has led to the use of both a forward and reverse output signal to measure suction or vacuum pressure in relation to ambient atmospheric air pressure.
0-24V to 4-20mA Signal Conversion
Convert a 0 to 24 volts range measurement input signal into a 4 to 20 milliamps loop output signal.
0-50mV to 0-10V Signal Conversion
Convert a 0 to 50 millivolts range measurement input signal into a 0 to 10 volts output signal.
0-30mV to 0-10V Signal Conversion
Convert a 0 to 30 millivolts range measurement input signal into a 0 to 10 volts output signal.
0-20mV to 0-10V Signal Conversion
Convert a 0 to 20 millivolts range measurement input signal into a 0 to 10 volts output signal.
0-50mV to 4-20mA Signal Conversion
Convert a 0 to 50 millivolts range measurement input signal into a 4 to 20 milliamps loop output signal.
0-30mV to 4-20mA Signal Conversion
Convert a 0 to 30 millivolts range measurement input signal into a 4 to 20 milliamps loop output signal.
0-20mV to 4-20mA Signal Conversion
Convert a 0 to 20 millivolts range measurement input signal into a 4 to 20 milliamps loop output signal.
HART® Liquid Level Transmitters
HART liquid level transmitters for configuration via a distributed control system (DCS) or HART communicator.
0…100 metres Liquid Level Range Sensor with 4-20mA Current Output Signal Transmitter
Measure liquid level over a 0 to 100 metres range and convert it to a 4 to 20 milliamps loop output signal.
0-50V to 0-10V Signal Conversion
Convert a 0 to 50 volt range measurement input signal into a 0 to 10 volts output signal.
0-50V to 1-5V Signal Conversion
Convert a 0 to 50 volt range measurement input signal into a 1 to 5 volts output signal.
0-50V to 0-5V Signal Conversion
Convert a 0 to 50 volt range measurement input signal into a 0 to 5 volts output signal.
0-50V to 0-20mA Signal Conversion
Convert a 0 to 50 volts range measurement input signal into a 0 to 20 milliamps loop output signal.
0-1V to 0-10V Signal Conversion
Convert a 0 to 1 volt range measurement input signal into a 0 to 10 volts output signal.
0-1V to 1-5V Signal Conversion
Convert a 0 to 1 volt range measurement input signal into a 1 to 5 volts output signal.
0-1V to 0-5V Signal Conversion
Convert a 0 to 1 volt range measurement input signal into a 0 to 5 volts output signal.
0-1V to 0-20mA Signal Conversion
Convert a 0 to 1 volt range measurement input signal into a 0 to 20 milliamps current output signal.
0-1V to 4-20mA Signal Conversion
Convert a 0 to 1 volt range measurement input signal into a 4 to 20 milliamps loop output signal.
Pressure Transducer 0.5-4.5V Voltage Output Calculator
This pressure transducer 0.5 to 4.5 volts amplified output calculator provides a way to determine the output reading from the applied pressure and pressure transducer range.
Pressure Transducer 1-5V Voltage Output Calculator
This pressure transducer 1 to 5 volts amplified output calculator provides a way to determine the output reading from the applied pressure and pressure transducer range.
Pressure Transducer 0-5V Voltage Output Calculator
This pressure transducer 0 to 5 volts amplified output calculator provides a way to determine the output reading from the applied pressure and pressure transducer range.
Pressure Transducer 0-10V Voltage Output Calculator
This pressure transducer 0 to 10 volts amplified output calculator provides a way to determine the output reading from the applied pressure and pressure transducer range.
Ratiometric V/V Signal to Measurement Converter
This ratiometric voltage input to measurement output converter provides a way to determine the measurement output reading and voltage input range from a ratiometric voltage input signal with a specified volts per volt span sensitivity, zero offset and supply voltage.
Measurement to Ratiometric V/V Signal Converter
This measurement to ratiometric voltage output calculator provides a way to determine the output reading and range of a ratiometric voltage signal sensing device from any measurement input, volts per volt span sensitivity, zero offset and supply voltage.
32…95°F Temperature Range Sensor with 4-20mA Current Output Signal Transmitter
Measure temperature over a 32 to 95 degrees Fahrenheit range and convert it to a 4 to 20 milliamps loop output signal.
0…35°C Temperature Range Sensor with 4-20mA Current Output Signal Transmitter
Measure temperature over a 0 to 35 degrees Celsius range and convert it to a 4 to 20 milliamps loop output signal.
14…140°F Temperature Range Sensor with 4-20mA Current Output Signal Transmitter
Measure temperature over a 14 to 140 degrees Fahrenheit range and convert it to a 4 to 20 milliamps loop output signal.
-10…+60°C Temperature Range Sensor with 4-20mA Current Output Signal Transmitter
Measure temperature over a -10 to +60 degrees Celsius range and convert it to a 4 to 20 milliamps loop output signal.
32…122°F Temperature Range Sensor with 4-20mA Current Output Signal Transmitter
Measure temperature over a 32 to 122 degrees Fahrenheit range and convert it to a 4 to 20 milliamps loop output signal.
0…50°C Temperature Range Sensor with 4-20mA Current Output Signal Transmitter
Measure temperature over a 0 to 50 degrees Celsius range and convert it to a 4 to 20 milliamps loop output signal.
32…212°F Temperature Range Sensor with 4-20mA Current Output Signal Transmitter
Measure temperature over a 32 to 212 degrees Fahrenheit range and convert it to a 4 to 20 milliamps loop output signal.
0…100°C Temperature Range Sensor with 4-20mA Current Output Signal Transmitter
Measure temperature over a 0 to 100 degrees Celsius range and convert it to a 4 to 20 milliamps loop output signal.
0-100mV to 0-10V Signal Conversion
Convert a 0 to 100 millivolts range measurement input signal into a 0 to 10 volts output signal.
0-100mV to 1-5V Signal Conversion
Convert a 0 to 100 millivolts range measurement input signal into a 1 to 5 volts output signal.
0-100mV to 0-5V Signal Conversion
Convert a 0 to 100 millivolts range measurement input signal into a 0 to 5 volts output signal.
0-100mV to 0-20mA Signal Conversion
Convert a 0 to 100 millivolts range measurement input signal into a 0 to 20 milliamps current output signal.
0-100mV to 4-20mA Signal Conversion
Convert a 0 to 100 millivolts range measurement input signal into a 4 to 20 milliamps loop output signal.
-5…+5V to 4…20mA Signal Conversion
Convert a -5 to +5 volts range measurement input signal into a 4 to 20 milliamps loop output signal.
-10…+10V to -5…+5V Bidirectional Signal Conversion
Convert a -10 to +10 volts range measurement input signal into a bidirectional -5 to +5 volts output signal.
-5…+5V to -10…+10V Bidirectional Signal Conversion
Convert a -5 to +5 volts range measurement input signal into a bidirectional -10 to +10 volts output signal.
4…20mA to -5…+5V Bidirectional Signal Conversion
Convert a 4 to 20 milliamps range measurement input signal into a bidirectional -5 to +5 volts output signal.
4…20mA to -10…+10V Bidirectional Signal Conversion
Convert a 4 to 20 milliamps range measurement input signal into a bidirectional -10 to +10 volts output signal.
1-5V to 0.5-4.5V Signal Conversion
Convert a 1 to 5 volts range measurement input signal into a 0.5 to 4.5 volts output signal.
0-10V to 0.5-4.5V Signal Conversion
Convert a 0 to 10 volts range measurement input signal into a 0.5 to 4.5 volts output signal.
0-5V to 0.5-4.5V Signal Conversion
Convert a 0 to 5 volts range measurement input signal into a 0.5 to 4.5 volts output signal.
0-20mA to 0.5-4.5V Signal Conversion
Convert a 0 to 20 milliamps range measurement input signal into a 0.5 to 4.5 volts output signal.
4-20mA to 0.5-4.5V Signal Conversion
Convert a 4 to 20 milliamps range measurement input signal into a 0.5 to 4.5 volts output signal.
0.5-4.5V to 0-10V Signal Conversion
Convert a 0.5 to 4.5 volts range measurement input signal into a 0 to 10 volts output signal.
0.5-4.5V to 1-5V Signal Conversion
Convert a 0.5 to 4.5 volts range measurement input signal into a 1 to 5 volts output signal.
0.5-4.5V to 0-5V Signal Conversion
Convert a 0.5 to 4.5 volts range measurement input signal into a 0 to 5 volts output signal.
0.5-4.5V to 0-20mA Signal Conversion
Convert a 0.5 to 4.5 volts range measurement input signal into a 0 to 20 milliamps current output signal.
0.5-4.5V to 4-20mA Signal Conversion
Convert a 0.5 to 4.5 volts range measurement input signal into a 4 to 20 milliamps loop output signal.
4-20mA to 20-4mA Signal Inversion
Invert a 4 to 20 milliamp current range measurement input signal into a 20 to 4 milliamp current output signal.
0-20mA to 20-0mA Signal Inversion
Invert a 0 to 20 milliamp current range measurement input signal into a 20 to 0 milliamp current output signal.
0-10V to 10-0V Signal Inversion
Invert a 0 to 10 volts range measurement input signal into a 10 to 0 volts output signal.
1-5V to 5-1V Signal Inversion
Invert a 1 to 5 volts range measurement input signal into a 5 to 1 volts output signal.
0-5V to 5-0V Signal Inversion
Invert a 0 to 5 volts range measurement input signal into a 5 to 0 volts output signal.
-10…+10V to 4…20mA Signal Conversion
Convert a -10 to +10 volts range measurement input signal into a 4 to 20 milliamps loop output signal.
0.5-4.5V to 4.5-0.5V Signal Inversion
Invert a 0.5 to 4.5 volts range measurement input signal into a 4.5 to 0.5 volts output signal.
0-50V to 4-20mA Signal Conversion
Convert a 0 to 50 volts range measurement input signal into a 4 to 20 milliamps loop output signal.
ECHO Mobile Network Battery Powered Multiple Sensor Telemetry Interface Unit
Mobile network communications and multichannel sensor signal input conditioner for installing in remote above or underground locations without a nearby power source or signal cables.
Ratiometric mV/V Signal to Measurement Converter
This ratiometric millivolt input to measurement output converter provides a way to determine the measurement output reading and millivolt input range from a ratiometric millivolt input signal with a specified millivolts per volt span sensitivity, zero offset and supply voltage.
Measurement to Ratiometric mV/V Signal Converter
This measurement to ratiometric millivolt output calculator provides a way to determine the output reading and range of a ratiometric millivolt signal sensing device from any measurement input, millivolts per volt span sensitivity, zero offset and supply voltage.
0-20mA Signal to Measurement Reading Converter
This current to measurement conversion tool will convert an electrical signal within the range of 0 to 20 milliamps to the ideal reading of any linear measurement type and create an incremental milliamp conversion scale for each measurement range entered.
0-10V Signal to Measurement Reading Converter
This voltage signal to measurement conversion tool will convert an electrical signal within the range of 0 to 10 volts to the ideal reading of any linear measurement type and create an incremental volts conversion scale for each measurement range entered.
0-5V Signal to Measurement Reading Converter
This voltage signal to measurement conversion tool will convert an electrical signal within the range of 0 to 5 volts to the ideal reading of any linear measurement type and create an incremental volts conversion scale for each measurement range entered.
1-5V Signal to Measurement Reading Converter
This voltage signal to measurement conversion tool will convert an electrical signal within the range of 1 to 5 volts to the ideal reading of any linear measurement type and create an incremental volts conversion scale for each measurement range entered.
0.5-4.5V Signal to Measurement Reading Converter
This voltage signal to measurement conversion tool will convert an electrical signal within the range of 0.5 to 4.5 volts to the ideal reading of any linear measurement type and create an incremental volts conversion scale for each measurement range entered.
SIAi-8 8 Channel Analogue Signal Input to RS-485 Modbus RTU Interface Converter
8 channel analogue signal to digital interface module for converting voltage or current signal inputs to a single RS-485 communication interface using Modbus RTU transmission protocol.
Totalizer
Total accumulated quantity of substance transferred.
USB
Universal Serial Bus (USB) interface computer connection
USB Pressure Sensors
Universal Serial Bus (USB) interface computer connection pressure sensing devices
DP Flow Transmitter Output Calculator
This differential pressure flow transmitter square root extraction 4 to 20 milliamp current output calculator provides a way to determine the flow output reading from the pressure drop measured across an orifice plate and the differential pressure transmitter range.
Liquid Level Transmitter 4-20mA Current Output Calculator
This liquid level transmitter 4 to 20 milliamp current output calculator provides a way to determine the output reading from the liquid level measurement and liquid level transmitter range
Flow Transmitter 4-20mA Current Output Calculator
This flow transmitter 4 to 20 milliamp current output calculator provides a way to determine the output reading from the measured flow and flow transmitter range.
Temperature Transmitter 4-20mA Current Output Calculator
This temperature transmitter 4 to 20 milliamp current output calculator provides a way to determine the output reading from the applied temperature and temperature transmitter range.
Pressure Transmitter 4-20mA Current Output Calculator
This pressure transmitter 4 to 20 milliamp current output calculator provides a way to determine the output reading from the applied pressure and pressure transmitter range.
Measurement Reading to 1-5V Signal Converter
This measurement to current converter tool will convert any linear input measurement reading into the ideal voltage output signal over a linear range of 1 to 5 volts, and display a 1-5V conversion scale for the chosen measurement range.
Measurement Reading to 0-5V Signal Converter
This measurement to voltage converter tool will convert any linear input measurement reading into the ideal voltage output signal over a linear range of 0 to 5 volts, and display a 0-5V conversion scale for the chosen measurement range.
Measurement Reading to 0-10V Signal Converter
This measurement to voltage converter tool will convert any linear input measurement reading into the ideal voltage output signal over a linear range of 0 to 10 volts, and display a 0-10V conversion scale for the chosen measurement range.