This DP sensor has response time of less than 5 milliseconds, and will measure the difference between the closed system and the surrounding air in both directions.
DMD341
5 psi dp 0-10V out air pressure sensor for automation flow rate testing use on a 15psi line
A low range differential pressure sensor for manufacturing automation flow rate testing use to measure pressure of air over a range of 0 to 5 psi diff on a 15 psi air line from two G1/8 female process connections, and sending the corresponding 0-10Vdc signal through the integral cable electrical connection.
3inH2O differential 4-20mA nitrogen pressure sensor and display for annealing furnace flow control use
A digital display and pressure sensor for annealing furnace flow control use to measure pressure of nitrogen over a range of 0 to 3 inH2O differential from two 1/8 NPT male process connections, and sending the corresponding 4-20mA signal through the M12 connector electrical connection.
10 mbar differential 0-10Vdc output air pressure sensor for building management use
A pressure sensor for building management use to measure pressure of air over a range of 0 to 10 mbar differential from two G1/8 female process connections, and sending the corresponding 0-10Vdc signal through the integral cable electrical connection.
15psi dp range 4-20mA air pressure sensor for chamber airflow testing use on a 15psi line
A pressure sensor for chamber air flow testing use to measure pressure of air over a range of 0 to 15 psi diff on a 15 psi air line from two G1/8 female process connections, and sending the corresponding 4-20mA signal through the DIN plug electrical connection.
Compressor inlet air filter pressure difference sensor
Measure the air intake filter pressure difference on an industrial air compressor with this -100 to +100 mb range, 0 to 10 volt output differential pressure sensor.
DMD341 Compact Differential Air Pressure Sensor
Small size dp sensor for measuring differential air pressure on HVAC, compress air and pneumatic control systems.
Vacuum differential pressure transducer with 60kPa range
Vacuum differential transducer for using with a variable frequency drive to control vacuum air pressures down to 60 kilopascals (kPa).
Air blower 100 inWG range differential pressure transducer
Differential air pressure transducer for air blower system to monitor pressures over the range of 0 to 100 inches of water with a 0 to 10 volt output.
5 psi delta air pressure sensor with 0 to 10 volt output
Delta pressure transducer for low range air pressure up to five psi with a zero to ten volt output signal.
1 psi delta air pressure sensor with 0 to 10 volt output
Delta pressure transducer for low range air pressure up to one psi with a zero to ten volt output signal.
5 psi delta air pressure sensor with 4 to 20 mA output
Delta pressure transmitter for low range air pressure up to five psi with a four to twenty milliamp current loop output.
1 psi delta pressure sensor with 4 to 20 mA output
Delta pressure sensor for measuring low range differential air pressure up to one psi with a four to twenty milliamp current loop output.