A complete clean room measurement system for 4 separate rooms, each with its own room pressure, humidity and air temperature indicator, and a central monitoring unit for clean room corridor or control room.
1 mbar
1 mbar, 0.4 inH2O Range 0-10 V, 0-5 V, 1-5 V Output Pressure Sensors
0…1 mbar or 0…0.4 inH2O pressure range, 0…10 V, 0…5 V, or 1…5 V output signal pressure sensors.
1 mbar, 0.4 inH2O, 100 Pa, 0.25 oz/in2 Range 4-20 mA Output Pressure Sensors
0…1 mbar, 0…0.4 inH2O, 0…100 Pa, or 0…0.25 oz/in2 pressure range, 4…20 mA output signal pressure sensors.
1 mbar range 4-20mA output biogas pressure transmitter for controlling blower fan connected to a covered lagoon
An intrinsically safe very low range pressure transmitter to measure pressure of biogas under covered lagoon to control a blower fan, over a range of 0 to 1 mbar g from the 1/4 inch NPT female tapered thread process connection, and sending the corresponding 4-20mA signal through the terminal clamps and M20 x 1.5 cable gland electrical connection.
ATEX rated room ±100 Pa differential pressure transmitter
Differential pressure transmitter with a -100 to +100 Pascal range for measuring the difference in pressure between the inside and the outside of a room, in an ATEX zone.
1 hPa Positive Room Pressure Sensor, Switch & Display
A 100 Pascal range positive room pressure sensor with a 0-10 volt analogue output signal relating to the inside/outside room pressure difference.
Low range ATEX approved 100 Pascal range DP transmitter
The DPT200 is a robust ATEX approved differential pressure transmitter which has a very low range of 100Pa.
Clean room temp, RH and pressure monitoring
Clean room monitor for temperature, relative humidity 0 to 99% RH and pressure from minus 100 to +100 Pa
Bi-directional -20 to +100 Pa clean room air diff pressure transmitter
Air diff pressure transmitter for HVAC application to measure in the range of -20 to +100 Pa with an active analog output of 4 – 20 mA
100 pascals range brick kiln and dryer air pressure logger and sensor
Logger with low bidirectional range differential sensor for recording brick kiln and dryer air pressures over the compound range of -100 to +100 Pa.
100 Pa bi-directional range differential air pressure transmitter
Bi-directional low range 4 to 20 milliamp differential pressure transmitter covering an air pressure range from -100 to +100 pascals.
0-100Pa air pressure transducer with a 0-10V analog output
Air pressure transducer for measuring 0 to 100 pascals with an analog output signal of 0 to 10 volts.
10 mmWC draft fan differential pressure transmitter
Low range dp transmitter for measuring 0… -10mmWC to maintain constant negative pressure across an induced draft fan fitted with a variable frequency drive.
Minus 100 pascal suction pressure transmitter
Very low range suction pressure transmitter for monitoring negative pressures up to 100 pascals.