25 mbar, 10 inH2O, 2500 Pa, 6 oz/in2 Range 4-20 mA Output Pressure Sensors

0…25 mbar, 0…10 inH2O, 0…2500 Pa, or 0…6 oz/in2 pressure range, 4…20 mA output signal pressure sensors.

These pressure sensors will measure from 0 to 25 millibars, 0 to 10 inches of water column, 0 to 2500 pascals, or 0 to 6 ounces per square inch pressure ranges, and convert the measured pressure to a corresponding output signal from 4 to 20 milliamps.

  • 90 degC air differential pressure transmitter and digital display
  • Minus 25 mb vacuum intrinsically safe 4-20mA pressure sensor
  • -10 to +10 inH2O Air Pressure Sensor for Ventilation & Extraction
  • Air scrubber 10 inH2O negative pressure transmitter

Contents

Toggle
  • Calibration Tables
    • 0…25 mbar to 4…20 mA
    • 0…10 inH2O to 4…20 mA
    • 0…2500 Pa to 4…20 mA
    • 0…6 oz/in2 to 4…20 mA

Calibration Tables

0…25 mbar to 4…20 mA

Use this table to determine the exact calibration points for a 0…25 millibars range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…25 mbar to 4…20 mA converter and enter any value.

% Scale 0…25mbar 4…20mA
0 0.00 4.00
10 2.50 5.60
20 5.00 7.20
30 7.50 8.80
40 10.00 10.40
50 12.50 12.00
60 15.00 13.60
70 17.50 15.20
80 20.00 16.80
90 22.50 18.40
100 25.00 20.00

Request product information for a 0...25 mbar to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.

0…10 inH2O to 4…20 mA

Use this table to determine the exact calibration points for a 0…10 inches of water column range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…10 inH2O to 4…20 mA converter and enter any value.

% Scale 0…10inH2O 4…20mA
0 0.00 4.00
10 1.00 5.60
20 2.00 7.20
30 3.00 8.80
40 4.00 10.40
50 5.00 12.00
60 6.00 13.60
70 7.00 15.20
80 8.00 16.80
90 9.00 18.40
100 10.00 20.00

Request product information for a 0...10 inH2O to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.

0…2500 Pa to 4…20 mA

Use this table to determine the exact calibration points for a 0…2500 pascals range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…2500 Pa to 4…20 mA converter and enter any value.

% Scale 0…2500Pa 4…20mA
0 0.00 4.00
10 250.00 5.60
20 500.00 7.20
30 750.00 8.80
40 1,000.00 10.40
50 1,250.00 12.00
60 1,500.00 13.60
70 1,750.00 15.20
80 2,000.00 16.80
90 2,250.00 18.40
100 2,500.00 20.00

Request product information for a 0...2500 Pa to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.

0…6 oz/in2 to 4…20 mA

Use this table to determine the exact calibration points for a 0…6 ounces per square inch range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…6 oz/in2 to 4…20 mA converter and enter any value.

% Scale 0…6oz/in2 4…20mA
0 0.00 4.00
10 0.60 5.60
20 1.20 7.20
30 1.80 8.80
40 2.40 10.40
50 3.00 12.00
60 3.60 13.60
70 4.20 15.20
80 4.80 16.80
90 5.40 18.40
100 6.00 20.00

Request product information for a 0...6 oz/in2 to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.

Primary Sidebar

Pressure Sensor Specifier

Specify a pressure sensor

Select your pressure sensor requirements

Pressure Sensor Calculator

Calculate errors and readings for a pressure sensor
Enter your parameters into this pressure sensor calculator to determine calibration errors, expected readings, and error tolerances

Pressure Sensor Technology Guide

Rating table for performance of different pressure sensor technology types

Compare performance of the most popular pressure sensor technology types and how they rate for different application requirements

Wirelessly Measure & Log 4-20mA

Use this battery powered wireless 4-20mA wireless transmitter to transmit readings to a receiver connected to USB, RS485, RS232, cellular network or analog output

Use this battery powered 4-20mA wireless transmitter to transmit readings to a receiver connected to USB, RS485, RS232, cellular network or analog output

Calibrate Low Pressure Measuring Devices

DPC controller and calibrator for calibrating low range air pressure sensors and instruments
DPC controller and calibrator for calibrating low range air pressure sensors and instruments

Products

  • Pressure
  • Level
  • Temperature
  • Interfacing
  • Datalogging
  • Calibration
  • Wireless

Product Enquiry

Send us your enquiry for a product associated with this 25 mbar, 10 inH2O, 2500 Pa, 6 oz/in2 Range 4-20 mA Output Pressure Sensors page, and get assistance with selecting a product for your application.

Email Your Enquiry

enquiries@sensorsone.com