20 mbar, 8 inH2O, 2000 Pa, 0.3 psi Range 4-20 mA Output Pressure Sensors

0…20 mbar, 0…8 inH2O, 0…2000 Pa, or 0…0.3 psi pressure range, 4…20 mA output signal pressure sensors.

These pressure sensors will measure from 0 to 20 millibars, 0 to 8 inches of water column, 0 to 2000 pascals, or 0 to 0.3 pounds per square inch pressure ranges, and convert the measured pressure to a corresponding output signal from 4 to 20 milliamps.

  • Biogas HDPE cover PD blower pressure sensor
  • Argon gas pressure sensor for 0-20mbar above atmospheric pressure
  • 20 mbarg digital display air pressure indicator and transmitter with 1/4 NPT male fitting
  • Biogas ATEX 4-20mA pressure transmitter for 0 to 20 mbar range

Contents

Toggle
  • Calibration Tables
    • 0…20 mbar to 4…20 mA
    • 0…8 inH2O to 4…20 mA
    • 0…2000 Pa to 4…20 mA
    • 0…0.3 psi to 4…20 mA

Calibration Tables

0…20 mbar to 4…20 mA

Use this table to determine the exact calibration points for a 0…20 millibars range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…20 mbar to 4…20 mA converter and enter any value.

% Scale 0…20mbar 4…20mA
0 0.00 4.00
10 2.00 5.60
20 4.00 7.20
30 6.00 8.80
40 8.00 10.40
50 10.00 12.00
60 12.00 13.60
70 14.00 15.20
80 16.00 16.80
90 18.00 18.40
100 20.00 20.00

Request product information for a 0...20 mbar to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.

0…8 inH2O to 4…20 mA

Use this table to determine the exact calibration points for a 0…8 inches of water column range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…8 inH2O to 4…20 mA converter and enter any value.

% Scale 0…8inH2O 4…20mA
0 0.00 4.00
10 0.80 5.60
20 1.60 7.20
30 2.40 8.80
40 3.20 10.40
50 4.00 12.00
60 4.80 13.60
70 5.60 15.20
80 6.40 16.80
90 7.20 18.40
100 8.00 20.00

Request product information for a 0...8 inH2O to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.

0…2000 Pa to 4…20 mA

Use this table to determine the exact calibration points for a 0…2000 pascals range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…2000 Pa to 4…20 mA converter and enter any value.

% Scale 0…2000Pa 4…20mA
0 0.00 4.00
10 200.00 5.60
20 400.00 7.20
30 600.00 8.80
40 800.00 10.40
50 1,000.00 12.00
60 1,200.00 13.60
70 1,400.00 15.20
80 1,600.00 16.80
90 1,800.00 18.40
100 2,000.00 20.00

Request product information for a 0...2000 Pa to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.

0…0.3 psi to 4…20 mA

Use this table to determine the exact calibration points for a 0…0.3 pounds per square inch range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…0.3 psi to 4…20 mA converter and enter any value.

% Scale 0…0.3psi 4…20mA
0 0.00 4.00
10 0.03 5.60
20 0.06 7.20
30 0.09 8.80
40 0.12 10.40
50 0.15 12.00
60 0.18 13.60
70 0.21 15.20
80 0.24 16.80
90 0.27 18.40
100 0.30 20.00

Request product information for a 0...0.3 psi to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.

Primary Sidebar

Pressure Sensor Specifier

Specify a pressure sensor

Select your pressure sensor requirements

Pressure Sensor Calculator

Calculate errors and readings for a pressure sensor
Enter your parameters into this pressure sensor calculator to determine calibration errors, expected readings, and error tolerances

Pressure Sensor Technology Guide

Rating table for performance of different pressure sensor technology types

Compare performance of the most popular pressure sensor technology types and how they rate for different application requirements

Wirelessly Measure & Log 4-20mA

Use this battery powered wireless 4-20mA wireless transmitter to transmit readings to a receiver connected to USB, RS485, RS232, cellular network or analog output

Use this battery powered 4-20mA wireless transmitter to transmit readings to a receiver connected to USB, RS485, RS232, cellular network or analog output

Calibrate Low Pressure Measuring Devices

DPC controller and calibrator for calibrating low range air pressure sensors and instruments
DPC controller and calibrator for calibrating low range air pressure sensors and instruments

Products

  • Pressure
  • Level
  • Temperature
  • Interfacing
  • Datalogging
  • Calibration
  • Wireless

Product Enquiry

Send us your enquiry for a product associated with this 20 mbar, 8 inH2O, 2000 Pa, 0.3 psi Range 4-20 mA Output Pressure Sensors page, and get assistance with selecting a product for your application.

Email Your Enquiry

enquiries@sensorsone.com
By clicking "OK" or continuing to use this website you are providing your consent to use cookies as described in our Privacy Policy

© 2025 SensorsONE Ltd, all rights reserved

  • Home
  • Products
  • Tools
  • Legal
  • Contact