0…150 mbar, 0…2 psi, 0…60 inH2O, or 0…15 kPa pressure range, 4…20 mA output signal pressure sensors.
These pressure sensors will measure from 0 to 150 millibars, 0 to 2 pounds per square inch, 0 to 60 inches of water column, or 0 to 15 kilopascals pressure ranges, and convert the measured pressure to a corresponding output signal from 4 to 20 milliamps.
Dust ATEX approved 2 psi pressure transmitter
15,000 Pa DP Transmitter with built-in digital display
Seawater solution 60 inH2O hydrostatic pressure sensor for 190degF temperature
Air classification system powder duct pressure transmitter with +/-15 kPa range and ATEX/IECEx IS cert
Calibration Tables
0…150 mbar to 4…20 mA
Use this table to determine the exact calibration points for a 0…150 millibars range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…150 mbar to 4…20 mA converter and enter any value.
% Scale | 0…150mbar | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 15.00 | 5.60 |
20 | 30.00 | 7.20 |
30 | 45.00 | 8.80 |
40 | 60.00 | 10.40 |
50 | 75.00 | 12.00 |
60 | 90.00 | 13.60 |
70 | 105.00 | 15.20 |
80 | 120.00 | 16.80 |
90 | 135.00 | 18.40 |
100 | 150.00 | 20.00 |
Request product information for a 0...150 mbar to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.
0…2 psi to 4…20 mA
Use this table to determine the exact calibration points for a 0…2 pounds per square inch range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…2 psi to 4…20 mA converter and enter any value.
% Scale | 0…2psi | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 0.20 | 5.60 |
20 | 0.40 | 7.20 |
30 | 0.60 | 8.80 |
40 | 0.80 | 10.40 |
50 | 1.00 | 12.00 |
60 | 1.20 | 13.60 |
70 | 1.40 | 15.20 |
80 | 1.60 | 16.80 |
90 | 1.80 | 18.40 |
100 | 2.00 | 20.00 |
Request product information for a 0...2 psi to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.
0…60 inH2O to 4…20 mA
Use this table to determine the exact calibration points for a 0…60 inches of water column range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…60 inH2O to 4…20 mA converter and enter any value.
% Scale | 0…60inH2O | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 6.00 | 5.60 |
20 | 12.00 | 7.20 |
30 | 18.00 | 8.80 |
40 | 24.00 | 10.40 |
50 | 30.00 | 12.00 |
60 | 36.00 | 13.60 |
70 | 42.00 | 15.20 |
80 | 48.00 | 16.80 |
90 | 54.00 | 18.40 |
100 | 60.00 | 20.00 |
Request product information for a 0...60 inH2O to 4...20 mA pressure sensor that matches the input and output measurement range from the calibration table above.
0…15 kPa to 4…20 mA
Use this table to determine the exact calibration points for a 0…15 kilopascals range to 4…20 milliamps output pressure sensor. For additional calibration points use our 0…15 kPa to 4…20 mA converter and enter any value.
% Scale | 0…15kPa | 4…20mA |
---|---|---|
0 | 0.00 | 4.00 |
10 | 1.50 | 5.60 |
20 | 3.00 | 7.20 |
30 | 4.50 | 8.80 |
40 | 6.00 | 10.40 |
50 | 7.50 | 12.00 |
60 | 9.00 | 13.60 |
70 | 10.50 | 15.20 |
80 | 12.00 | 16.80 |
90 | 13.50 | 18.40 |
100 | 15.00 | 20.00 |